Technical data sheet · PowerEdge XE · 4U dual-socket, eight PCIe GPUs

Dell PowerEdge XE7740Specifications, configurations & comparisons

The XE7740 is Dell’s air-cooled 4U PCIe GPU server for Intel Xeon 6: up to eight double-wide 600 W accelerators or sixteen single-width L4s on a switched PCIe board, with eight Gen5 slots for the cluster network and eight power supplies in two zones. This page sets out what Dell documents, including the memory-per-GPU rules and NVLink bridge options.

4U Rack2 socketsXeon 6 P-coreiDRAC10
8double-wide GPUsup to 600 W each · or 16 × L4
86cores per CPUXeon 6 6787P · 3 SKUs
4TBDDR5 maximum32 × 128 GB RDIMM
8PCIe Gen5 x16 slotsfor NICs · plus OCP 3.0
8E3.S NVMe bays122.88 TB maximum
8power supplies3200 W or 2400 W · 2 CPU + 6 GPU zone

Every figure checked against the Dell PowerEdge XE7740 Technical Guide (Rev. A04, April 2026)

Form factor
4U Rack · 2 sockets
Processors
Xeon 6 P-core
Memory
32 × DDR5 RDIMM · up to 4 TB
Drive bays
Up to 8 · 1 drive-bay layout
Expansion
8 × PCIe · 1 × OCP 3.0
GPUs
Up to 16 · 6 listed
Boot
BOSS-N1 DC-MHS (HW RAID 1, 2 x M.2 NVMe SSD)
Management
iDRAC10
01 — Overview

The XE7740 at a glance

Our read of Dell’s documentation: where the XE7740 is strong, and the limits worth knowing before you spec one.

Strengths

  • Eight double-wide slots at up to 600 W accept five different cards — NVIDIA H100 NVL, H200 NVL, L40S and RTX Pro 6000, or Intel Gaudi 3 — or sixteen single-width L4s.
  • NVLink is available through bridges: 2-way for H100 NVL pairs and 4-way for groups of four H200 NVL cards.
  • Eight Gen5 x16 adapter slots at up to 150 W each give one fabric slot per double-wide GPU, with 400GbE and 200GbE cards in Dell’s port table.
  • All three processors, every DIMM size and most GPUs are cleared at 35°C on air alone, with no liquid-cooling requirement.
  • Eight supplies in separate CPU and GPU zones support A/B grid operation that rides through up to four supply losses at reduced performance.

Watch-outs

  • Only three processors are offered, all 330–350 W Xeon 6 P-core parts, and the system is two-socket only.
  • Memory is tied to GPU count: eight H200 NVL, H100 NVL or RTX Pro 6000 cards need at least 1.5 TB, and Dell warns that unvalidated pairings can stop the system booting.
  • H200 NVL and most RTX Pro 6000 layouts are limited to a 30°C inlet, 5°C below the rest of the list.
  • Storage is fixed at eight E3.S bays with no RAID controller, and the chassis weighs up to 71.35 kg.
  • Dell measured up to 87 dB at the bystander position at 35°C, recommends ear protection and positions the server for unattended data centres.
Processors3 SKUs
Cores / CPU48–86
DIMM slots32
Drive layouts1
Max bays8
GPUsup to 16
PSU options3 · to 3,200 W
02 — Processors

3 supported processors, mapped

Dell lists just three processors, all Intel Xeon 6 6700P P-core parts, and two are always fitted. The trade is cores against clock: the 6747P gives 48 cores at 2.7 GHz and 330 W, the 6767P 64 at 2.4 GHz, and the 6787P 86 at 2.0 GHz, both at 350 W.

Processor landscape — cores × TDP

3 SKUs · 1 family
Dell PowerEdge XE7740: every supported processor by cores and TDP0816243240485664728088300 W350 WCores per processorIntel Xeon 6 6787P — 86 cores / 172 threads · 350 W · 2 GHz base · 336 MB cache · DDR5-6400Intel Xeon 6 6767P — 64 cores / 128 threads · 350 W · 2.4 GHz base · 336 MB cache · DDR5-6400Intel Xeon 6 6747P — 48 cores / 96 threads · 330 W · 2.7 GHz base · 288 MB cache · DDR5-64006 6787P86 cores · 4.1 W/core — top SKU and most efficient
Xeon 6 P-core 3Bubble size = L3 cache · hover a bubble for the full SKU

Processor explorer

filter · sort · compare
ProcessorCores / threadsBaseL3 cacheTDPW / coreMemory
Intel Xeon 6 6787P86 / 1722 GHz336 MB350 W4.1DDR5-6400
Intel Xeon 6 6767P64 / 1282.4 GHz336 MB350 W5.5DDR5-6400
Intel Xeon 6 6747P48 / 962.7 GHz288 MB330 W6.9DDR5-6400
  • Each processor supplies 88 PCIe 5.0 lanes, with bifurcation down to x2, and connects to its partner over as many as four 24 GT/s UPI links.
  • A single CPU heat sink type covers every TDP, and Dell’s thermal matrix clears all three processors at 35°C on HPR Platinum fans. That matrix lists the 6747P at 350 W, against 330 W in the processor table.
  • Dell’s processor table has no turbo column; for all three it lists 6400 MT/s memory and a 4 TB capacity figure, which is the system maximum (16 slots × 128 GB is 2 TB per processor).
  • Intel Software Guard Extensions (SGX) is among the processor features Dell names for application isolation.
03 — Memory

32 DIMM slots, 16 per processor

Thirty-two DDR5 RDIMM slots, sixteen per socket in eight channels of two. The distinctive rule here is that Dell sets minimum memory by GPU count: eight H200 NVL, H100 NVL or RTX Pro 6000 cards need at least 1.5 TB (16 × 96 GB) or 2 TB, and smaller footprints are marked Not Validated.

Capacity with every slot filled

by DIMM size
32 GB1 TB64 GB2 TB96 GB3 TB128 GB4 TB32 slots · 16 per processor · each tick = one DIMM

Operating speed

per Dell memory tables
Processor1 DIMM / channel2 DIMMs / channel
Xeon 6 6700P (all three SKUs)6400 MT/s5200 MT/s
  • Eight Gaudi 3 cards are validated with 32 × 64 GB, 32 × 96 GB or 128 GB modules; 16 × 96 GB, accepted for eight NVIDIA cards, is not validated with them.
  • A 512 GB build (16 × 32 GB) is validated only with two H200 NVL, H100 NVL or RTX Pro 6000 cards, four or eight L40S, or four L4s.
  • Dell cautions that unvalidated memory and GPU pairings can cause GPU performance loss, PCIe fatal errors, or a failure to power on or reach the operating system.
  • One DIMM per channel keeps 6400 MT/s, so 16 × 128 GB gives 2 TB at full speed; filling all 32 slots drops to 5200 MT/s.
  • The May 2025 spec sheet still quotes 3 TB, with 128 GB modules as a future option; the April 2026 guide lists 128 GB RDIMMs and 4 TB.
04 — Storage

1 drive-bay layout, up to 8 bays

Local storage is a single layout of eight EDSFF E3.S Gen5 NVMe bays, direct-attached, with 122.88 TB as Dell’s ceiling. There are no rear bays, no internal or external RAID controller and no Dell software RAID.

Headline layouts

front panel view

Front panel

8 × EDSFF NVMe at the front — 8 bays in total.

SAS/SATANVMeSAS/SATA + NVMe

Controllers & boot

  • BOSS-N1 DC-MHS — Boot. HW RAID 1, 2 x M.2 NVMe; slot 41 x4. No internal/external PERC or software RAID offered (Table 2: N/A)
  • BOSS-N1 DC-MHS (HW RAID 1, 2 x M.2 NVMe SSD) — boot
  • Listed drives run from 1.6 TB to 15.36 TB in Mixed Use (3 drive writes per day) and Read Intensive (1 per day) classes, all with Instant Secure Erase.
  • The operating system boots from a BOSS-N1 DC-MHS module at the front, with two M.2 NVMe SSDs in hardware RAID 1 on a x4 link (slot 41).
  • Dell’s thermal tables assume the 8 × E3.S front with no rear drives for every processor, memory and GPU entry.
05Accelerators & I/O

GPUs, PCIe and networking

Accelerators plug into a PCIe Base Board (PBB) with four PCIe switches, two under each processor, feeding sixteen full-height, full-length x16 slots numbered 21–36. Double-wide cards use the odd-numbered slots, eight in all, filled from the middle outwards: 25, 27, 29 and 31 first, then 21, 23, 33 and 35. Single-width L4s can occupy all sixteen. Up to 8 × double-wide at up to 600 W (NVIDIA H100 NVL, H200 NVL, L40S, RTX Pro 6000; Intel Gaudi 3) or 16 × single-width L4, with NVLink bridges for H100 NVL (2-way) and H200 NVL (4-way).

NVIDIA H200 NVL 141GB

double-wide
141GB · up to 8

NVIDIA H100 NVL 94GB

double-wide
94GB · up to 8

NVIDIA RTX Pro 6000 96GB

double-wide
96GB · up to 8

NVIDIA L40S 48GB

double-wide
48GB · up to 8

NVIDIA L4 24GB

single-wide
24GB · up to 16

Intel Gaudi 3 128GB

double-wide
128GB · up to 8

I/O topology

88 lanes per CPU
CPU 188 × PCIe 5.08 ch · 16 DIMMCPU 288 × PCIe 5.08 ch · 16 DIMMUPI 2.0 · up to 4 links · 24 GT/s8 × PCIe Gen5 x16 FH-HLslots 1–4 & 6–9 · up to 150 W16 GPU slots on the PBB4 PCIe switches · 8 DW or 16 SWOCP 3.0 slot 5 (Gen5 x8)up to 2 ports · 100GbE maxBOSS-N1 DC-MHSslot 41 · x4 · RAID 1 boot

Each Xeon 6 processor supplies 88 PCIe 5.0 lanes. Besides the sixteen internal GPU slots, the rear offers eight full-height, half-length Gen5 x16 slots for adapters of up to 150 W — slots 1–4 on processor 1 and 6–9 on processor 0 — which is one network slot per double-wide GPU in a full build.

Network adapters Dell lists

11 options
AdapterPortsForm
Mellanox 2 x 25GbE SFP28 OCP 3.02 × 25GbEOCP 3.0
Mellanox 2 x 100GbE QSFP56 OCP 3.02 × 100GbEOCP 3.0
Intel 2 x 10GbE BASE-T OCP 3.02 × 10GbEOCP 3.0
Broadcom 4 x 25GbE SFP28 OCP 3.04 × 25GbEOCP 3.0
Broadcom 2 x 100GbE BT OCP 3.02 × 100GbEOCP 3.0
Broadcom 2 x 10GbE BASE-T OCP 3.02 × 10GbEOCP 3.0
Broadcom 2 x 25GbE SFP28 OCP 3.02 × 25GbEOCP 3.0
DPU card (B3220) 2 x 200GbE2 × 200GbEPCIe
PCIe add-in NIC 1 x 400GbE1 × 400GbEPCIe
PCIe add-in NIC 2 x 200GbE2 × 200GbEPCIe
PCIe add-in NIC 2 x 100GbE2 × 100GbEPCIe
  • Dell’s port table lists add-in NICs at 1 × 400GbE, 2 × 200GbE and 2 × 100GbE, plus the B3220 DPU with 2 × 200GbE, without naming adapter models.
  • The B3220 DPU is limited to 30°C ambient on DAC cables and does not support active optical cables; OCP cards of 100Gb and above need 85°C-rated optics or DAC.
  • Only the OCP card in slot 5 can redirect the iDRAC port as a shared NIC.
  • Fitting PCIe devices Dell has not validated, or adding or removing GPUs without consulting Dell, can void the warranty if damage results.
06 — Power & cooling

3 power supplies, 2,400–3,200 W

Eight 73.5 mm supplies in two zones: PSUs 1–2 feed the 1U CPU tray and PSUs 3–8 the 3U GPU zone. Each zone needs at least one unit for standby power, full redundancy means 1+1 plus 3+3, and a system started with one supply halts with an error. Units are 3200 W or 2400 W Titanium, or 3200 W for 277 V AC / HVDC.

05001000150020002500300035002400 W Titanium — Mixed mode multi-capacity: 2400 W at 200-240 V AC, 1400 W at 100-120 V AC; 240 V DC (10.9 A). C19 cord. 8x 600 W DW GPUs not supported on 2400 W in 4+0/3+1 or 3+3 A/B-grid configurations (Table 27)2400Titanium3200 W Titanium — Mixed mode multi-capacity: 3200 W at 220.1-240 V AC (16 A), 2900 W at 200-220 V AC; 240 V DC (14.5 A). C19 cord. 73.5 mm form factor3200Titanium3200 W Titanium — 277 V AC (12.9 A) and 336 V DC HVDC (10.47 A); APP/Saf-D-Grid cable3200TitaniumWatts · dashed line = output at 100–120 V low line
AC277 VAC / HVDC
  • In Dell’s 3200 W matrix, four supplies (one CPU-zone, three GPU-zone) run every GPU loadout only as non-redundant; the 3+1 layout is unsupported and A/B grid needs all eight.
  • With 2400 W supplies, eight 600 W cards (H200 NVL, RTX Pro 6000 or Gaudi 3) need all eight units in 8+0 or 7+1, not A/B grid, and six H200 NVL or RTX Pro 6000 are also excluded from A/B grid.
  • The 3200 W unit delivers 3200 W at 220.1–240 V AC but 2900 W at 200–220 V; the 2400 W unit falls to 1400 W on 100–120 V. Both use C19 leads, and the 277 V AC / HVDC model uses APP/Saf-D-Grid.
  • Both redundant policies support GPU power braking, and Dell offers no user power cap on this model. Supplies from mixed sub-vendors are not supported.
07 — Management, security & OS

Run it, secure it, choose the OS

Management

  • iDRAC10 (Datacenter licence adds GPU and DPU management and telemetry streaming)
  • iDRAC Direct (front USB-C)
  • iDRAC RESTful API with Redfish
  • RACADM CLI and IPMI
  • iDRAC Service Module
  • Zero-Touch Provisioning
  • OpenManage Enterprise with Power Manager, Services and Update Manager
  • Enterprise Catalogs and Linux repositories

Security

  • Silicon Root of Trust
  • Cryptographically signed firmware
  • Secure Boot
  • Secured Component Verification
  • Data at Rest Encryption (SEDs, local or external key management)
  • System Lockdown
  • Secure Erase
  • TPM 2.0 FIPS, CC-TCG certified
  • Chassis intrusion detection

Operating systems

  • Canonical Ubuntu Server LTS
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware ESXi
08 — Compare

How the XE7740 compares with its family

The XE7740 is the Intel half of a pair: the XE7745 shares its dimensions, GPU slot layout and two-zone power with AMD EPYC 9005 processors and 24 DIMM slots. For SXM GPUs the range moves to the four-GPU XE8640 and the eight-GPU XE9680 and XE9780, while the 2U R770 takes two double-wide cards.

XE7740XE7745XE8640XE9680XE9780R770R760xaCores / CPUXE7740: 8686XE7745: 192192XE8640: 6464XE9680: 6464XE9780: 8686R770: 144144R760xa: 6464DIMM slotsXE7740: 3232XE7745: 2424XE8640: 3232XE9680: 3232XE9780: 3232R770: 3232R760xa: 3232Max memoryXE7740: 4 TB4XE7745: 6 TB6XE8640: 4 TB4XE9680: 4 TB4XE9780: 4 TB4R770: 8 TB8R760xa: 8 TB8Max drive baysXE7740: 88XE7745: 88XE8640: 88XE9680: 1616XE9780: 1616R770: 4444R760xa: 88Max GPUsXE7740: 1616XE7745: 1616XE8640: 44XE9680: 88XE9780: 88R770: 66R760xa: 1212Largest PSUXE7740: 3,200 W3,200XE7745: 3,200 W3,200XE8640: 3,200 W3,200XE9680: 3,200 W3,200XE9780: 3,200 W3,200R770: 3,200 W3,200R760xa: 3,200 W3,200
This modelSiblings and successorEach value from that model’s own verified spec file · bars scale per column
09 — Use cases

Four builds that suit the XE7740

Four XE7740 builds, each matched to a row of Dell’s GPU, memory and power tables. Every ID is on the configurator’s list for this model, so a build loads there ready to adjust.

LLM inference

Eight-card H200 NVL inference server

Eight H200 NVL cards hold 8 × 141 GB = 1,128 GB of GPU memory. Dell documents this loadout both unbridged and with two 4-way NVLink bridges, preferably one group of four per processor; the bridges are not part of this configurator build. 32 × 64 GB of DDR5 is one of the memory layouts Dell validates for eight cards, eight E3.S drives keep model weights local, and a 400GbE adapter links the node to the cluster.

  • 2 × Xeon 6 6767P64 cores @ 2.4 GHz, 350 W each
  • 8 × NVIDIA H200 NVL 141 GB (double-wide, up to 600 W)
  • 32 × 64 GB DDR5-6400 RDIMM — 2 TB at 5200 MT/s
  • 8 × 7.68 TB E3.S Gen5 NVMe — 61.44 TB raw
  • BOSS-N1 DC-MHS boot pair (RAID 1)
  • 1 × 400GbE PCIe network adapter
  • 8 × 3200 W Titanium (1+1 CPU zone, 3+3 GPU zone)
  • Ubuntu Server 24.04 LTS

Dell rates H200 NVL for a 30°C inlet. If bridges are added, they must come off with Dell’s NVL bridge removal tool, two per bridge, and full power redundancy needs all eight supplies.

Open this build in the configurator →
Fine-tuning

Intel Gaudi 3 fine-tuning node

Gaudi 3 is the non-NVIDIA option on the XE7740: eight 128 GB cards at 600 W, rated for 35°C inlet. Dell validates eight of them with 32 × 64 GB, the layout used here, and the 86-core 6787P provides the most host threads on the list (172 per socket) for data preparation.

  • 2 × Xeon 6 6787P86 cores @ 2 GHz, 350 W each
  • 8 × Intel Gaudi 3 128 GB (double-wide, 600 W)
  • 32 × 64 GB DDR5-6400 RDIMM — 2 TB at 5200 MT/s
  • 4 × 15.36 TB E3.S Gen5 NVMe — 61.44 TB raw
  • BOSS-N1 DC-MHS boot pair (RAID 1)
  • 1 × 400GbE PCIe network adapter
  • 8 × 3200 W Titanium
  • Ubuntu Server 22.04 LTS

The May 2025 spec sheet marked Gaudi 3 as coming later; the April 2026 guide lists it as supported. 16 × 96 GB is not validated with eight Gaudi 3 cards.

Open this build in the configurator →
Dense inference

Sixteen-L4 inference server

Sixteen single-width L4s fill every GPU slot, each drawing 72 W in Dell’s power tables. The 48-core 6747P is the lowest-TDP host (330 W in Dell’s processor table), 1 TB of DDR5 at one DIMM per channel holds 6400 MT/s, and with all eight 2400 W supplies Dell’s matrix supports sixteen L4s in every redundancy mode, 4+4 A/B grid included.

  • 2 × Xeon 6 6747P48 cores @ 2.7 GHz, 330 W each
  • 16 × NVIDIA L4 24 GB (single-width)
  • 16 × 64 GB DDR5-6400 RDIMM — 1 TB at 6400 MT/s
  • 8 × 3.84 TB E3.S Gen5 NVMe — 30.72 TB raw
  • BOSS-N1 DC-MHS boot pair (RAID 1)
  • Mellanox 2 × 100GbE QSFP56 OCP 3.0
  • 8 × 2400 W Titanium
  • Red Hat Enterprise Linux 9

Dell’s memory-validation table covers four and eight L4s, not sixteen, so we confirm the memory layout with Dell for a full build. Its 16 × L4 acoustic test measured 72 dB at the bystander position at 25°C.

Open this build in the configurator →
Digital twins

Four RTX Pro 6000 digital-twin host

Digital twins are one of the workloads Dell names for this server. Four RTX Pro 6000 cards (96 GB each) in the middle PCIe slots are rated to 35°C, where other RTX Pro 6000 layouts stop at 30°C. 16 × 96 GB satisfies Dell’s memory table for four cards at 6400 MT/s, and the 277 V AC / HVDC supplies suit halls with that distribution.

  • 2 × Xeon 6 6767P64 cores @ 2.4 GHz, 350 W each
  • 4 × NVIDIA RTX Pro 6000 96 GB (double-wide, up to 600 W)
  • 16 × 96 GB DDR5-6400 RDIMM — 1.5 TB at 6400 MT/s
  • 4 × 15.36 TB E3.S Gen5 NVMe — 61.44 TB raw
  • BOSS-N1 DC-MHS boot pair (RAID 1)
  • Broadcom 2 × 100GbE OCP 3.0
  • 8 × 3200 W Titanium, 277 V AC or 336 V DC
  • Ubuntu Server 24.04 LTS

The 35°C rating applies only with the four cards in the middle PCIe slots. The 277 V AC / HVDC supplies take APP/Saf-D-Grid cords.

Open this build in the configurator →
10 — Full specifications

Dell PowerEdge XE7740 specifications

Chassis & cooling

Form factor4U rack server, two sockets · 1U CPU zone above a 3U GPU zone
Dimensions174.3 mm high × 482 mm wide · 899.56 mm deep with bezel, 886.73 mm without
WeightUp to 71.35 kg (157.30 lb)
CoolingAir only
Fans4 dual-fan HPR Platinum modules in the mid tray + 12 HPR Platinum front fans, all hot-swap · N+1
RailsB37 stab-in sliding rails (sliding only)
BezelOptional security bezel

Processor

SocketsTwo
ProcessorsIntel Xeon 6 6747P (48 cores), 6767P (64), 6787P (86)
TDP330 W (6747P) or 350 W · the thermal matrix lists all three at 350 W
UPIUp to 4 links at 24 GT/s
PCIe lanes88 × Gen5 per processor
ChipsetNone listed (N/A in Dell’s table)

Memory

Slots32 DDR5 RDIMM · 16 per processor · 8 channels × 2 DIMMs
Modules32, 64, 96 and 128 GB, dual-rank, 1.1 V
Speed6400 MT/s at 1 DPC · 5200 MT/s at 2 DPC
Maximum4 TB (32 × 128 GB)
GPU pairingMinimum validated capacity rises with GPU count (Tables 10–13)

Storage

Front8 × EDSFF E3.S Gen5 NVMe, direct-attached
Drives1.6 TB to 15.36 TB · 122.88 TB maximum
Rear / RAIDNo rear bays · no PERC · no software RAID
BootBOSS-N1 DC-MHS: 2 × M.2 NVMe, hardware RAID 1

Accelerators

Double-wideUp to 8 at up to 600 W: NVIDIA H100 NVL, H200 NVL, L40S, RTX Pro 6000 · Intel Gaudi 3
Single-widthUp to 16 × NVIDIA L4
GPU slots16 × Gen5 x16 full-height, full-length on the PCIe Base Board · 4 PCIe switches
NVLinkH100 NVL: 2-way bridges, three per pair · H200 NVL: 4-way bridges, one per four cards
Inlet limitsH200 NVL and RTX Pro 6000 30°C (RTX Pro 6000 35°C with four in the middle slots) · others 35°C

Expansion & networking

PCIe8 × Gen5 x16 full-height, half-length, up to 150 W each (slots 1–4 and 6–9)
OCP1 × OCP 3.0 SFF, Gen5 x8 · up to 2 ports, 100GbE maximum
Add-in NICs1 × 400GbE · 2 × 200GbE · 2 × 100GbE · B3220 DPU 2 × 200GbE
Management port1GbE dedicated iDRAC port on the DC-SCM

Power

Supplies8 × 73.5 mm hot-plug · PSUs 1–2 CPU zone · PSUs 3–8 GPU zone
AC3200 W Titanium (2900 W at 200–220 V) · 2400 W Titanium (1400 W at 100–120 V) · C19 leads
277 V AC / HVDC3200 W Titanium, 277 V AC or 336 V DC · APP/Saf-D-Grid
RedundancyNon-redundant, PSU-redundant or A/B grid · full redundancy 1+1 and 3+3

Ports & video

FrontUSB 2.0 Type-C (host / iDRAC Direct) · optional USB 2.0 Type-A and Mini-DisplayPort
RearDedicated iDRAC port · VGA · 2 × USB 3.1 Type-A
Internal1 × USB 3.1 Type-A
VideoIntegrated Matrox G200, 16 MB

Environment & acoustics

Operating rangeASHRAE A2, 10–35°C
Sound power (8 × H100 NVL test build)8.3 B idle, 9.0 B operating at 25°C · up to 10.3 B at 35°C
HearingDell highly recommends ear protection during operation
11 — FAQ

XE7740 questions, answered from the documentation

What is the maximum memory of the Dell PowerEdge XE7740?

Thirty-two DDR5 RDIMM slots reach 4 TB with 128 GB modules, running at 5200 MT/s with two per channel. One module per channel keeps 6400 MT/s and gives 2 TB with 128 GB parts. Dell also sets minimums by GPU count: eight H200 NVL, H100 NVL or RTX Pro 6000 cards need at least 1.5 TB.

Which GPUs does the XE7740 support?

Up to eight double-wide PCIe cards at up to 600 W — NVIDIA H100 NVL, H200 NVL, L40S or RTX Pro 6000, or Intel Gaudi 3 — or up to sixteen single-width NVIDIA L4s. They sit on a PCIe Base Board behind four PCIe switches, and double-wide cards go into the four middle odd-numbered slots (25–31) before the outer ones (21, 23, 33, 35).

Does the XE7740 support NVLink?

Yes, through bridges on the NVL cards. H100 NVL pairs use three 2-way bridges each, six for four cards and twelve for eight, while H200 NVL uses one 4-way bridge per four cards. Dell advises bridging only cards under the same processor. There is no NVLink baseboard as in SXM systems such as the XE8640.

Which processors does the XE7740 support?

Three Intel Xeon 6 6700P P-core models: the 6747P (48 cores, 2.7 GHz, 330 W), 6767P (64 cores, 2.4 GHz, 350 W) and 6787P (86 cores, 2.0 GHz, 350 W). Two are always fitted, and all three are rated for 35°C inlet on HPR Platinum fans.

How many network slots does the XE7740 have for a GPU cluster?

Eight Gen5 x16 full-height, half-length slots for adapters of up to 150 W each, plus one Gen5 x8 OCP 3.0 slot. Dell’s port table lists add-in NICs up to 1 × 400GbE or 2 × 200GbE and a B3220 DPU with 2 × 200GbE, while OCP cards top out at 2 × 100GbE.

What power supplies does the XE7740 need?

Eight hot-plug supplies in two zones: two for the CPU tray and six for the GPU zone, with at least one required in each. Options are 3200 W Titanium (2900 W below 220 V), 2400 W Titanium and 3200 W for 277 V AC or 336 V DC. Eight 600 W GPUs on 2400 W units need all eight supplies and cannot use A/B grid.

How many drives does the XE7740 hold?

Eight EDSFF E3.S Gen5 NVMe SSDs at the front, up to 122.88 TB, plus a BOSS-N1 boot module with two M.2 NVMe drives in RAID 1. There are no rear bays and no PERC or software RAID option.

How big, heavy and loud is the XE7740?

It is 4U: 174.3 mm high, 482 mm wide and 899.56 mm deep with the bezel, weighing up to 71.35 kg, which puts it in Dell’s server-lift class. Dell measured up to 10.3 B of sound power at 35°C and advises against acoustically sensitive locations, recommending ear protection.

How does the XE7740 differ from the XE7745?

The XE7745 keeps the same dimensions, GPU slots and power zones but uses two AMD EPYC 9005 processors of up to 192 cores and 24 DIMM slots for 6 TB. Its GPU list adds the AMD Instinct MI350P and RTX Pro 4500 and drops Gaudi 3. The XE7740 has 32 DIMM slots and Intel Xeon 6.

Is the Dell PowerEdge XE7740 end of life?

Dell’s XE7740 guide (Rev. A04, April 2026) publishes no end-of-sale or end-of-support date. Our end-of-life checker shows Dell’s dates once they appear.

Sources & verification

Where these figures come from

Specifications are extracted from Dell’s published documents and independently re-checked line by line. Configurations are quote-based; availability and exact options are confirmed at quotation. Last reviewed 2026-09-11.

Get a quote for the Dell PowerEdge XE7740

Tell us the workload and we’ll spec and price it — or build it in the configurator first.

Business enquiries only — please use your company email. Gmail, Hotmail and other personal addresses are not accepted.

We only ship hardware to the countries in the dropdown. Software and maintenance services are global.

Enquiring about: Dell PowerEdge XE7740

Response within 4 business hours · No obligation

Quote for
Dell PowerEdge XE7740
0800 987 4111

Talk to a UK specialist

Get expert advice or a no-obligation quote — servers, storage, networking, maintenance, finance and cloud. We reply the same working day.

or call 0800 987 4111