Technical data sheet · PowerEdge XE · 10U dual-socket, eight-GPU, air-cooled

Dell PowerEdge XE9780Specifications, configurations & comparisons

The XE9780 is Dell’s 10U air-cooled training server: two Xeon 6 processors driving an eight-GPU NVIDIA HGX B300 or B200 board, fed by twelve 3200 W supplies and cooled by a wall of fans instead of a liquid loop. Below is what Dell’s technical guide documents for it, including how the choice of GPU board changes the slots, networking and operating systems you get.

10U Rack2 socketsXeon 6 P-coreiDRAC10
8GPUs on one HGX boardHGX B300 NVL8 or HGX B200
86cores per CPU4 Xeon 6 P-core SKUs
4TBDDR5 maximum32 × 128 GB RDIMM
16E3.S Gen5 NVMe baysor 10 × U.2 Gen5 (post-RTS)
12Gen5 x16 slots with B2004 with B300, plus 8 × OSFP
12× 3200 W suppliesTitanium · 6+6 redundant

Every figure checked against the Dell PowerEdge XE9780 Technical Guide (Rev. A03, August 2026)

Form factor
10U Rack · 2 sockets
Processors
Xeon 6 P-core
Memory
32 × DDR5 RDIMM · up to 4 TB
Drive bays
Up to 16 · 2 drive-bay layouts
Expansion
12 × PCIe · 1 × OCP 3.0
GPUs
Up to 8 · 2 listed
Boot
BOSS-N1 DC-MHS (2 x M.2 SSDs)
Management
iDRAC10
01 — Overview

The XE9780 at a glance

Our read of Dell’s documentation: where the XE9780 is strong, and the limits worth knowing before you spec one.

Strengths

  • A choice of two eight-GPU HGX boards: B300 NVL8 with 270 GB per GPU at 1100 W, or B200 with 180 GB at 1000 W, all eight GPUs joined by NVLink.
  • Air is the only cooling option in Dell’s feature table — 15 hot-swap GPU fans and five CPU fans, rated across a 10–35°C inlet range.
  • With B300, eight OSFP ports from embedded ConnectX-8 NICs are built in, and the four remaining PCIe slots take NICs or DPUs.
  • With B200, twelve front Gen5 x16 slots accept up to twelve ConnectX-7 NDR 400G InfiniBand or 200 GbE cards.
  • All I/O and expansion faces the front — OCP card, iDRAC ports, BOSS-N1, drives and PCIe cards; the rear carries only fans and supplies.

Watch-outs

  • Ten rack units, 439.5 mm tall and up to 163.20 kg fully populated: Dell requires a lift, and supports up to four per IR5048 or IR5052 rack.
  • It is 1044.7 mm deep with the bezel, and Dell warns that the length can foul rear-mounted PDUs or the rear rack door.
  • Choosing B300 cuts the PCIe complement from twelve slots to four — numbers 3, 6, 9 and 12, each rated to 150 W.
  • The twelve supplies deliver 3200 W only on 216.1–240 V AC or 240 V DC, drop to 2900 W at 200–216 V, and have no low-line rating.
  • Operating-system support is narrow: Ubuntu Server LTS for either board, Red Hat Enterprise Linux only with B300, and OpenManage Enterprise and its plug-ins are listed as post-RTS.
Processors4 SKUs
Cores / CPU48–86
DIMM slots32
Drive layouts2
Max bays16
GPUsup to 8
PSU options1 · to 3,200 W
02 — Processors

4 supported processors, mapped

Dell qualifies only four Xeon 6 P-core processors here, from the 48-core 6747P at 2.7 GHz to the 86-core 6787P at 2.0 GHz, all rated at 330 W or 350 W. Dell’s thermal matrix clears all four with both the B300 and the B200 board.

Processor landscape — cores × TDP

4 SKUs · 1 family
Dell PowerEdge XE9780: every supported processor by cores and TDP0816243240485664728088300 W350 WCores per processorIntel Xeon 6 6787P — 86 cores / 172 threads · 350 W · 2 GHz base · 336 MB cache · DDR5-6400Intel Xeon 6 6767P — 64 cores / 128 threads · 350 W · 2.4 GHz base · 336 MB cache · DDR5-6400Intel Xeon 6 6776P — 64 cores / 128 threads · 350 W · 2.3 GHz base · 336 MB cache · DDR5-6400Intel Xeon 6 6747P — 48 cores / 96 threads · 330 W · 2.7 GHz base · 288 MB cache · DDR5-64006 6787P86 cores · 4.1 W/core — top SKU and most efficient
Xeon 6 P-core 4Bubble size = L3 cache · hover a bubble for the full SKU

Processor explorer

filter · sort · compare
ProcessorCores / threadsBaseL3 cacheTDPW / coreMemory
Intel Xeon 6 6787P86 / 1722 GHz336 MB350 W4.1DDR5-6400
Intel Xeon 6 6767P64 / 1282.4 GHz336 MB350 W5.5DDR5-6400
Intel Xeon 6 6776P64 / 1282.3 GHz336 MB350 W5.5DDR5-6400
Intel Xeon 6 6747P48 / 962.7 GHz288 MB330 W6.9DDR5-6400
  • Every listed processor uses a 2U extended heat sink with standard fans in both GPU configurations — there are no fan tiers to choose.
  • Dell’s processor table gives each part 24 GT/s UPI, 6400 MT/s memory and 4 TB of memory capacity, and marks turbo only as present.
  • The guide’s generic processor-family figures — up to 144 cores in the processor chapter and a 500 W maximum TDP in Table 1 — exceed all four parts cleared for this chassis.
  • The socket is Intel’s 4710-pin package, with up to four UPI 2.0 links per processor.
03 — Memory

32 DIMM slots, 16 per processor

The 32 RDIMM slots split sixteen to a processor over eight DDR5 channels and take 64, 96 or 128 GB modules at 1.1 V. The unusual rule here is a floor, not a ceiling: Dell’s guide relays an NVIDIA design-guide requirement that an eight-GPU system hold more than 1 TB of memory in total with B200, and more than 2 TB with B300.

Capacity with every slot filled

by DIMM size
64 GB2 TB96 GB3 TB128 GB4 TB32 slots · 16 per processor · each tick = one DIMM

Operating speed

per Dell memory tables
Processor1 DIMM / channel2 DIMMs / channel
Xeon 6 P-core (all four listed SKUs)6400 MT/s5200 MT/s
  • The 4 TB maximum is 32 × 128 GB. Dell says it would rise to 8 TB if 256 GB DIMMs were supported after launch, but lists no such module.
  • For B300, 16 × 128 GB gives exactly 2 TB and misses the more-than-2 TB rule; the balanced fills that clear it are 32 × 96 GB (3 TB) and 32 × 128 GB (4 TB), both at two DIMMs per channel and 5200 MT/s.
  • For B200, 16 × 96 GB (1.5 TB) or 16 × 128 GB (2 TB) clears the 1 TB rule at one DIMM per channel and keeps 6400 MT/s.
  • Dell requires DIMM blanks whenever fewer than 16 modules are fitted, and notes that the top speed depends on processor and population.
04 — Storage

2 drive-bay layouts, up to 16 bays

Storage is deliberately plain: sixteen E3.S Gen5 NVMe bays attached directly from the PSB at x4 Gen5, or ten 2.5-inch U.2 Gen5 NVMe bays listed as post-RTS. There is no PERC, no SAS or SATA and no hard-disk option; Dell’s S160 software RAID is the only array layer for the data drives.

Headline layouts

front panel view

Front panel

16 × EDSFF NVMe at the front — 16 bays in total.

SAS/SATANVMeSAS/SATA + NVMe

Controllers & boot

  • Software RAID S160 — Software RAID. Drives are direct-attached PCIe NVMe only ('Direct attached PCIe only'); PERC qty 0 in both storage configs; no PERC/HBA offered
  • BOSS-N1 DC-MHS — Boot. Integrated (front I/O), 2 x M.2 SSDs
  • BOSS-N1 DC-MHS (2 x M.2 SSDs) — boot
  • Dell’s configuration matrix calls the E3.S layout C01 and the U.2 layout C02; both need two processors and fit no PERC.
  • Boot is separate from the data bays: a BOSS-N1 DC-MHS module with two M.2 SSDs sits in the front I/O area.
  • The guide gives no drive capacity table for this model, so raw capacity depends on the E3.S drives quoted.
  • Empty drive, M.2 and OCP positions need blanks, and every empty PCIe slot needs a GYP32 blank.

Every documented layout

2 with drive bays
10 x 2.5-inch U.2 Gen5 NVMe direct from PSB, confi…10 x 2.5-inch U.2 Gen5 NVMe direct from PSB, config C02 (post-RTS), Software RAID S1601016 x E3.S EDSFF Gen5 NVMe direct from PSB (x4 Gen5…16 x E3.S EDSFF Gen5 NVMe direct from PSB (x4 Gen5), config C01, Software RAID S16016Bays · solid = front · dashed = rear · brighter = NVMe-only
2.5-inch3.5-inchEDSFF (E1.S / E3.S)
05Accelerators & I/O

GPUs, PCIe and networking

The GPU complex is an eight-way NVIDIA HGX board on its own sled, fitted in internal slots 21–28, with an NVSwitch cover across its centre and the rear fan wall cooling it. Dell pairs each board with a different base board — B200 with the PSBB, B300 with the PCIe Switch Retimer Base Board (PSRBB) — and the two configurations expose different front slots. One of two mutually exclusive boards: 8 × HGX B300 NVL8 (270 GB, 1100 W) or 8 × HGX B200 (180 GB, 1000 W), fully interconnected with NVLink. Table 1 lists both as SXM6; Table 2 prints SXM7 for B300. B300 adds eight embedded ConnectX-8 OSFP ports.

NVIDIA HGX B300 NVL8 270GB SXM6 (8-GPU baseboard, PSRBB config)

270GB · 8 (fixed 8-way)

NVIDIA HGX B200 180GB SXM6 (8-GPU baseboard, PSBB config)

180GB · 8 (fixed 8-way)

I/O topology

2 sockets
CPU 1PCIe 5.08 ch · 16 DIMMCPU 2PCIe 5.08 ch · 16 DIMMUPI 2.0 · up to 4 links · 24 GT/sB200: 12 × Gen5 x16 FHHL8 × 75 W + 4 × up to 150 WB300: 4 × Gen5 x16 FHHLslots 3, 6, 9, 12 · up to 150 W8 × CX-8 OSFP (B300 only)OSFP boards on the GPU sled1 × OCP 3.0 SFF · frontplus 2 × iDRAC RJ45 · BOSS-N1

All PCIe is Gen5 x16 full-height, half-length and sits on the front face, alongside a single OCP 3.0 card. Slots 2–7 hang off CPU 2 and slots 8–13 off CPU 1 in Dell’s slot matrix, and the usable set depends on the GPU board.

Network adapters Dell lists

27 options
AdapterPortsForm
8 x NVIDIA CX-8 OSFP (embedded on GPU sled, B300 configuration only)8 × OSFP (speed not stated)embedded
Broadcom 2 x 100 GbE Q56 OCP 3.0 (DPN J6CC8)2 × 100GbEOCP 3.0
Broadcom 2 x 200 GbE QSFP OCP 3.0 (DPN T635T)2 × 200GbEOCP 3.0
NVIDIA 2 x 100 GbE QSFP OCP 3.0 (DPN 769PV)2 × 100GbEOCP 3.0
Broadcom 4 x 25 GbE QSFP OCP 3.0 (DPN YD26W)4 × 25GbEOCP 3.0
NVIDIA 2 x 25 GbE QSFP OCP 3.0 (DPN 7GGY4)2 × 25GbEOCP 3.0
Broadcom 2 x 25 GbE QSFP OCP 3.0 (DPN 313Y1)2 × 25GbEOCP 3.0
Intel 2 x 10 GbE BT OCP 3.0 (DPN FC0HK)2 × 10GbEOCP 3.0
Broadcom 2 x 10 GbE QSFP OCP 3.0 (DPN MN1T3)2 × 10GbEOCP 3.0
Intel OCP 3.0 100 GB dual port (slot-priority Table 16)2 × 100GbEOCP 3.0
Intel OCP 3.0 25 GB dual port (slot-priority Table 16)2 × 25GbEOCP 3.0
Intel OCP 3.0 25 GB quad port (slot-priority Table 16)4 × 25GbEOCP 3.0
Intel OCP 3.0 10 GB dual port (post RTS; slot-priority Table 16)2 × 10GbEOCP 3.0
Intel OCP 3.0 10 GB quad port (slot-priority Table 16)4 × 10GbEOCP 3.0
Broadcom OCP 3.0 10 GB quad port (slot-priority Table 16)4 × 10GbEOCP 3.0
Broadcom OCP 3.0 1 GB quad port (slot-priority Table 15)4 × 1GbEOCP 3.0
NVIDIA Mellanox ConnectX-7 NDR 400G InfiniBand 1 x OSFP (B200 config, up to 12)1 × 400GPCIe
NVIDIA Mellanox ConnectX-7 200G QSFP112 Gen5 dual port (B200 config, up to 12)2 × 200GPCIe
Broadcom 1000BASE-T 1 GB quad port (B200 config, up to 12)4 × 1GbEPCIe
Broadcom BCM5719 1 GB quad port (B200 config, up to 12)4 × 1GbEPCIe
NVIDIA DPU FH 200 GB (B300 config, slots 6/9/3/12, up to 4; BlueField-3 B3220/B3240 per thermal matrix) × 200GPCIe
NVIDIA DPU FH 400 GB (post RTS; B300 config, up to 4) × 400GPCIe
NVIDIA OSFP NIC 400G NDR (B300 config, up to 4) × 400GPCIe
Broadcom NIC 200 GB dual port (B300 config, up to 4)2 × 200GPCIe
NVIDIA NIC 400 GB single port / 100 GB dual port (B300 config, up to 4) × 400G / 100GPCIe
Intel NIC 100 GB dual port (B300 config, up to 4)2 × 100GPCIe
Broadcom NIC 100 GB dual port (B300 config, up to 4)2 × 100GPCIe
  • In B200 builds Dell’s fill order for network cards starts at slots 4, 8, 7 and 11 and finishes at 3 and 12; in B300 builds NICs and DPUs use slots 6, 9, 3 and 12, at most four cards.
  • NVIDIA DPUs B3220 and B3240 appear in Dell’s thermal table only for the B300 configuration.
  • The OCP bay is Gen5 x8 in Dell’s Table 1 but Gen4 x8 (35 W, 200 GbE maximum) in its OCP 3.0 feature list (Table 11). Only the Broadcom and NVIDIA dual-port 25 GbE cards were available at RTS.
  • Table 2 lists the embedded NIC as N/A, although the appendix’s NIC section opens with a generic line about two 10/100/1000 Mbps LOM ports; its port table lists only the two front iDRAC RJ45 ports and the OCP card. iDRAC Direct over USB Type-C is the other management route.
06 — Power & cooling

1 power supply, 3,200 W

Twelve 3200 W Titanium supplies in a 73.5 mm × 185 mm form factor, run as 6+6 for full redundancy or split across A and B grids. Each is one multi-rated unit: 3200 W on 216.1–240 V AC or 240 V DC, 2900 W on 200–216 V AC, and 5280 W peak on high line.

05001000150020002500300035003200 W Titanium — 3200 W Mixed Mode (Multi-rated) AC at 216.1-240 V AC, 16 A, 11,850 BTU/hr; 12 PSUs per system, 6+6 full redundancy (FR) or A/B grid redundant; 73.5 mm x 185 mm form factor, 54 V DC output to internal busbar, C19/C20 cord; peak 5280 W highline; efficiency 90/94/96/91% at 10/20/50/100% load. Auto-sensing/auto-switching. Same single SKU also rated 3200 W on 240 V DC input (14.5 A, 11,850 BTU/hr) and derated to 2900 W at 200-216 V AC low-line (16.0 A, 10,750 BTU/hr) - these are input-voltage operating points of the one 3200 W Mixed Mode (Multi-rated) PSU (Tables 18/30), not separate PSU options.3200TitaniumWatts · dashed line = output at 100–120 V low line
AC
  • Each supply takes a C19 lead into a C20 inlet and outputs 54 V; Dell’s HPM-sled figure also labels a power interposer board, a power distribution board and busbar cables.
  • Dell rates the supply’s efficiency at 90% (10% load), 94% (20%), 96% (50%) and 91% (full load); that efficiency table (Table 31) gives the form factor as 86 mm, against 73.5 mm elsewhere in the guide.
  • Each supply dissipates up to 11,850 BTU/hr at its 3200 W rating, or 10,750 BTU/hr in the 2900 W mode.
  • There is no low-line or −48 V DC rating, and the XE9780 supports neither a user power cap nor Sound Cap; Dell points to its EIPT tool for sizing.
07 — Management, security & OS

Run it, secure it, choose the OS

Management

  • iDRAC10 (Datacenter licence available as an upsell)
  • iDRAC Direct over USB Type-C (optional 2.5 GbE dongle)
  • Two front dedicated iDRAC RJ45 ports
  • iDRAC RESTful API with Redfish
  • RACADM CLI and IPMI
  • iDRAC Service Module
  • OpenManage Enterprise with Power Manager, Service and Update Manager plug-ins (post-RTS)
  • CloudIQ for PowerEdge plug-in
  • Ansible, Terraform, ServiceNow and BMC TrueSight integrations

Security

  • Silicon Root of Trust
  • Cryptographically signed firmware
  • Secure Boot
  • Secured Component Verification
  • Secure Enterprise Key Management
  • Data at Rest Encryption (SEDs, local or external key management)
  • System Lockdown (iDRAC10 Enterprise or Datacenter)
  • Secure Erase
  • Soldered-down TPM

Operating systems

  • Canonical Ubuntu Server LTS (B300 and B200)
  • Red Hat Enterprise Linux (B300 only)
08 — Compare

XE9680 → XE9780

Dell’s Table 2 sets the XE9780 beside the 6U XE9680. Alongside the move to Xeon 6, the table shows new HGX boards, direct-attached NVMe in place of PERC, and a chassis that grows from 6U to 10U.

Previous generationPowerEdge XE9680
Xeon 6 · HGX B300 / B200PowerEdge XE9780
Processors
2 × 5th Gen Xeon Scalable (to 64 cores) or 4th Gen (to 56 cores)
2 × Xeon 6 P-core, up to 86 cores
Memory speed
5600 / 4400 MT/s (5th Gen) · 4800 / 4400 MT/s (4th Gen), 1 / 2 DPC
6400 / 5200 MT/s, 1 / 2 DPC
Maximum memory
4 TB RDIMM
4 TB RDIMM (8 TB if 256 GB DIMMs are supported post-RTS)
GPUs
HGX H100/H800, H200, H20, A100 · AMD MI300X · Intel Gaudi3
HGX B300 NVL8 1100 W or HGX B200 1000 W
Drive bays
16 × E3.S · 8 × U.2 SAS/SATA with fPERC · 8 × U.2 NVMe
16 × E3.S · 10 × U.2 Gen5 NVMe (post-RTS)
Storage controllers
PERC12 (SAS4/SATA) · BOSS-N1
Direct-attached PCIe SSDs only
PCIe
10 × Gen5 x16 FHHL, 2 of them for SmartNIC/DPU
12 × Gen5 x16 FHHL (B200) · 4 (B300)
Networking
2 × 1 GbE LOM · OCP x8 Mezz 3.0
No LOM · 1 × OCP 3.0 · 8 × OSFP with B300
Power
3200 W (US & Canada only), 3000 W (Gaudi3) or 2800 W Titanium
12 × 3200 W Titanium
Fans
HPR Gold: 6 mid-tray + 10 rear GPU fans
Standard grade: 5 CPU (cold-swap) + 15 GPU (hot-swap)
Size
6U · 263.2 mm high · 482.0 mm wide · 1008.77 mm deep with bezel
10U · 439.5 mm high · 448.0 mm wide · 1044.7 mm deep with bezel
Management
iDRAC9
iDRAC10
Operating systems
Ubuntu, RHEL, SLES · ESXi (H100 only)
Ubuntu (B300, B200) · RHEL (B300)

Source: Dell PowerEdge XE9780 Technical Guide (Rev. A03, August 2026), Table 2 (features of the XE9780 and XE9680).

The XE9780 family side by side

The XE9780 is Dell’s air-cooled Xeon 6 host for an eight-GPU HGX B300 or B200 board. The XE9785 keeps the 10U air-cooled HPM-plus-GPU-sled design with AMD EPYC 9005 processors and a choice of AMD Instinct MI355X or HGX B300; the XE9780L puts the same four processors and both HGX boards into a liquid-cooled 3 OU node for IR7044/IR7050 racks. The 6U XE9680 is the predecessor.

XE9780XE9780L/XE9780LAPXE9785XE9785LXE9680XE9680LCores / CPUXE9780: 8686XE9780L/XE9780LAP: 128128XE9785: 192192XE9785L: 192192XE9680: 6464XE9680L: 6464DIMM slotsXE9780: 3232XE9780L/XE9780LAP: 3232XE9785: 2424XE9785L: 2424XE9680: 3232XE9680L: 3232Max memoryXE9780: 4 TB4XE9780L/XE9780LAP: 4 TB4XE9785: 6 TB6XE9785L: 3 TB3XE9680: 4 TB4XE9680L: 4 TB4Max drive baysXE9780: 1616XE9780L/XE9780LAP: 1616XE9785: 1616XE9785L: 1616XE9680: 1616XE9680L: 88Max GPUsXE9780: 88XE9780L/XE9780LAP: 88XE9785: 88XE9785L: 88XE9680: 88XE9680L: 88Largest PSUXE9780: 3,200 W3,200XE9780L/XE9780LAP: 33,000 W33,000XE9785: 3,200 W3,200XE9785L: 33,000 W33,000XE9680: 3,200 W3,200XE9680L: 3,000 W3,000
This modelSiblings and successorEach value from that model’s own verified spec file · bars scale per column
09 — Use cases

Four builds that suit the XE9780

Four eight-GPU builds that follow the slot, memory and operating-system rules in Dell’s XE9780 guide. Each opens pre-filled in the configurator with parts it allows on this model; supply count and fabric adapters are finalised on the quote.

Foundation-model training

B300 training node on air

Eight B300 GPUs with 270 GB each, driven by two 86-core 6787P processors and cooled by air alone, with no liquid loop to plumb. Its 3 TB of memory clears the more-than-2 TB floor NVIDIA sets for B300 systems, and Red Hat Enterprise Linux is supported with this board.

  • 2 × Xeon 6 6787P86 cores @ 2 GHz, 350 W each
  • NVIDIA HGX B300 NVL8 board — 8 × 270 GB GPUs, 1100 W each
  • 32 × 96 GB DDR5 RDIMM — 3 TB at 5200 MT/s
  • 16 × 7.68 TB E3.S Gen5 NVMe — 122.88 TB raw, S160 software RAID
  • BOSS-N1 DC-MHS boot module (2 × M.2)
  • 8 × OSFP ports from the embedded ConnectX-8 NICs
  • Broadcom 2 × 200 GbE QSFP OCP 3.0
  • 12 × 3200 W Titanium (6+6)
  • Red Hat Enterprise Linux 9

With B300 only four front slots (3, 6, 9, 12) stay usable. The 200 GbE OCP card was listed as post-RTS. Supplies reach 3200 W only on 216.1–240 V AC or 240 V DC; we confirm all twelve on the quote.

Open this build in the configurator →
Multi-node training

B200 node with a wide InfiniBand fan-out

The B200 configuration keeps all twelve front Gen5 x16 slots, and Dell allows up to twelve single-port ConnectX-7 NDR 400G InfiniBand cards in them, filled from slots 4, 8, 7 and 11 first. That is enough for one adapter per GPU with four slots left for storage or management networks.

  • 2 × Xeon 6 6767P64 cores @ 2.4 GHz, 350 W each
  • NVIDIA HGX B200 board — 8 × 180 GB GPUs, 1000 W each
  • 32 × 64 GB DDR5 RDIMM — 2 TB at 5200 MT/s
  • 8 × 3.84 TB E3.S Gen5 NVMe — 30.72 TB raw
  • BOSS-N1 DC-MHS boot module (2 × M.2)
  • NVIDIA ConnectX-7 NDR 400G InfiniBand, 1 × OSFP (up to 12 per node)
  • 12 × 3200 W Titanium (6+6)
  • Ubuntu Server 24.04 LTS

Ubuntu Server LTS is the only operating system Dell lists with B200. The configurator adds one fabric card; the adapter count is set on the quote. Memory must stay above 1 TB with B200.

Open this build in the configurator →
Fine-tuning & inference

B200 server with 245 TB of local flash

For teams that fine-tune or serve models from datasets held on the node, every E3.S bay is filled, and one DIMM per channel keeps memory at 6400 MT/s. The 48-core 6747P has the highest base clock Dell lists for this chassis, 2.7 GHz.

  • 2 × Xeon 6 6747P48 cores @ 2.7 GHz, 330 W each
  • NVIDIA HGX B200 board — 8 × 180 GB GPUs
  • 16 × 128 GB DDR5 RDIMM — 2 TB at 6400 MT/s, one per channel
  • 16 × 15.36 TB E3.S Gen5 NVMe — 245.76 TB raw
  • BOSS-N1 DC-MHS boot module (2 × M.2)
  • Broadcom 2 × 100 GbE Q56 OCP 3.0
  • 12 × 3200 W Titanium (6+6)
  • Ubuntu Server 24.04 LTS

Dell’s XE9780 guide has no drive capacity table, so E3.S sizes are confirmed when we quote. S160 software RAID is the only array option for these drives; there is no PERC.

Open this build in the configurator →
HPC & simulation

4 TB B300 host for memory-heavy simulation

Dell names HPC compute and simulation among the XE9780’s target workloads. This build fills all 32 slots with 128 GB modules for the 4 TB maximum, beside the 64-core 6776P and the 2.16 TB of GPU memory on a B300 board.

  • 2 × Xeon 6 6776P64 cores @ 2.3 GHz, 350 W each
  • NVIDIA HGX B300 NVL8 board — 8 × 270 GB GPUs
  • 32 × 128 GB DDR5 RDIMM — 4 TB at 5200 MT/s, the chassis maximum
  • 8 × 7.68 TB E3.S Gen5 NVMe — 61.44 TB raw
  • BOSS-N1 DC-MHS boot module (2 × M.2)
  • Broadcom 2 × 200 GbE PCIe NIC (slot 6 first)
  • 12 × 3200 W Titanium (6+6)
  • Red Hat Enterprise Linux 9

With B300, PCIe NICs go in slots 6, 9, 3 and 12, up to four cards; the eight OSFP ports come from the embedded ConnectX-8 NICs.

Open this build in the configurator →
10 — Full specifications

Dell PowerEdge XE9780 specifications

Chassis & cooling

Form factor10U rack server · HPM (host) sled and GPU sled · front I/O
Dimensions439.5 mm high · 448.0 mm wide (482.3 mm at Xa) · 1044.7 mm deep with bezel, 1023 mm without
Weight163.20 kg with B200 · 159.65 kg with B300 (fully populated, 16 × E3.S)
CoolingAir only · 15 hot-swap GPU fans in a rear fan sled · 5 cold-swap CPU fans on the mid tray
Fan redundancyTwo-rotor modules; runs on with one rotor failed · a removed GPU fan must be refitted within 30 seconds
BezelOptional front bezel or security bezel
RailsStatic rails only · no cable management arm · up to four per IR5048 or IR5052 rack

Processor

SocketsTwo
Supported partsIntel Xeon 6 6787P, 6767P, 6776P and 6747P
Cores per processor48 to 86
TDP330 W or 350 W
UPIUp to 4 × UPI 2.0 links at 24 GT/s
Cooling2U extended heat sink with standard fans

Memory

Slots32 × DDR5 RDIMM (288-pin) · 16 per processor · 8 channels
Modules64, 96 and 128 GB · 2R x4 · 1.1 V
Speed6400 MT/s at 1 DPC · 5200 MT/s at 2 DPC
Maximum4 TB (32 × 128 GB) · 8 TB only if 256 GB DIMMs are supported post-RTS
Minimum (NVIDIA)More than 1 TB with B200 · more than 2 TB with B300

Storage

Front bays16 × E3.S Gen5 NVMe (C01) · 10 × 2.5" U.2 Gen5 NVMe (C02, post-RTS)
ControllerDirect-attached PCIe · S160 software RAID · no PERC
BootBOSS-N1 DC-MHS with 2 × M.2 SSDs

Expansion & networking

PCIe with B20012 × Gen5 x16 FHHL, slots 2–13 · 8 × 75 W + 4 × up to 150 W
PCIe with B3004 × Gen5 x16 FHHL, slots 3, 6, 9 and 12 · up to 150 W
Embedded OSFP8 × OSFP from ConnectX-8 NICs (B300 only)
OCP1 × OCP 3.0 SFF at the front · Gen5 x8 (Table 1) / Gen4 x8, 35 W (Table 11)
DPUNVIDIA B3220 or B3240, B300 configuration only
LOMEmbedded NIC N/A in Table 2 (the appendix text mentions LOM ports its port table omits)

Accelerators

GPU boardNVIDIA HGX B300 NVL8 (8 × 270 GB, 1100 W) or HGX B200 (8 × 180 GB, 1000 W)
Form factorSXM6 (Table 2 prints SXM7 for B300)
InterconnectNVLink across all eight GPUs · NVSwitch under a cover mid-board
LocationGPU sled, internal slots 21–28 · PSBB (B200) or PSRBB (B300) base board

Power

Supplies12 × 3200 W Titanium · 73.5 × 185 mm (Table 31: 86 mm) · 54 V output
Redundancy6+6 full redundancy, or A/B grid redundancy set in iDRAC
Input3200 W at 216.1–240 V AC or 240 V DC · 2900 W at 200–216 V AC · C19 cord
Peak5280 W per supply on high line
Efficiency90 / 94 / 96 / 91% at 10 / 20 / 50 / 100% load

Ports & video

FrontUSB 2.0 and Mini-DisplayPort (left panel) · USB Type-C host / iDRAC Direct (right panel) · 2 × iDRAC RJ45
Internal1 × USB 3.1
VideoIntegrated Matrox G200, 16 MB

Environment

Operating range10–35°C (ASHRAE A2) · no A3 or A4 configurations
AltitudeUp to 3,048 m operating · maximum temperature falls 1°C per 300 m above 900 m
11 — FAQ

XE9780 questions, answered from the documentation

Which GPUs does the Dell PowerEdge XE9780 support?

One eight-GPU NVIDIA HGX board: either HGX B300 NVL8 with 270 GB per GPU at 1100 W, or HGX B200, whose GPUs carry 180 GB each and draw 1000 W, all fully linked by NVLink. Dell’s overview lists both as SXM6, while its Table 2 prints SXM7 for B300. The two are separate configurations, each with its own PCIe base board, so the GPU choice also fixes the slot layout.

What is the maximum memory of the XE9780?

Four terabytes, from 32 × 128 GB DDR5 RDIMMs at 5200 MT/s. Dell says 8 TB would follow if 256 GB modules were supported after launch. There is also a minimum: more than 1 TB with B200 and more than 2 TB with B300, per NVIDIA’s design guide.

How many drive bays does the XE9780 have?

Sixteen E3.S Gen5 NVMe bays, or ten 2.5-inch U.2 Gen5 NVMe bays listed as post-RTS. Drives attach directly over PCIe with S160 software RAID; there is no PERC, SAS or SATA option. Boot uses a separate BOSS-N1 module with two M.2 SSDs.

How many PCIe slots does the XE9780 have?

Twelve Gen5 x16 full-height, half-length slots with the B200 board (eight at 75 W and four at up to 150 W), but only four (slots 3, 6, 9 and 12) with B300, which adds eight embedded ConnectX-8 OSFP ports instead. A single OCP 3.0 card and the BOSS-N1 module are extra to those slots.

What power does the XE9780 need?

Twelve 3200 W Titanium supplies on C19 leads, in 6+6 redundancy or split across A and B grids. Each delivers 3200 W at 216.1–240 V AC or 240 V DC and 2900 W at 200–216 V AC, with no low-line rating. The server does not support a user power cap.

How big and heavy is the PowerEdge XE9780?

It is a 10U chassis, 439.5 mm high, 448.0 mm wide and 1044.7 mm deep with the bezel (1023 mm without). Fully populated it weighs 163.20 kg with B200 or 159.65 kg with B300, so a lift is required, and Dell supports up to four in an IR5048 or IR5052 rack.

Does the XE9780 need liquid cooling?

No. Air is the only cooling option Dell lists: 15 hot-swap GPU fans at the rear and five cold-swap CPU fans, across a 10–35°C inlet range, with no ASHRAE A3 or A4 configurations. The liquid-cooled version is the separate XE9780L, a 3 OU compute node that lives in Dell’s IR7044 or IR7050 racks.

What changed from the XE9680 to the XE9780?

Dell’s comparison moves the host from 4th/5th Gen Xeon Scalable (up to 64 cores) to Xeon 6 at up to 86 cores, raises memory speed to 6400 MT/s and swaps the H100, H800, H200, H20, A100, MI300X and Gaudi3 boards for HGX B300 or B200. The chassis grows from 6U to 10U, PERC and the LOM disappear, and power moves to twelve 3200 W supplies.

Which operating systems run on the XE9780?

Dell lists Canonical Ubuntu Server LTS with either board and Red Hat Enterprise Linux with B300 only. No Windows Server, SUSE or VMware support appears in the guide, whereas the XE9680 listed SLES and ESXi.

Is the Dell PowerEdge XE9780 end of life?

Dell’s guide gives no end-of-sale or end-of-support date for it, and the August 2026 revision (Rev. A03) still marks several options as post-RTS. Dell’s XE servers carry a standard three-year hardware warranty; our end-of-life checker records dates once Dell publishes them.

Sources & verification

Where these figures come from

Specifications are extracted from Dell’s published documents and independently re-checked line by line. Configurations are quote-based; availability and exact options are confirmed at quotation. Last reviewed 2026-09-11.

Get a quote for the Dell PowerEdge XE9780

Tell us the workload and we’ll spec and price it — or build it in the configurator first.

Business enquiries only — please use your company email. Gmail, Hotmail and other personal addresses are not accepted.

We only ship hardware to the countries in the dropdown. Software and maintenance services are global.

Enquiring about: Dell PowerEdge XE9780

Response within 4 business hours · No obligation

Quote for
Dell PowerEdge XE9780
0800 987 4111

Talk to a UK specialist

Get expert advice or a no-obligation quote — servers, storage, networking, maintenance, finance and cloud. We reply the same working day.

or call 0800 987 4111