Technical data sheet · ProLiant Gen11 · 2U four-socket

HPE ProLiant DL560 Gen11Specifications, configurations & comparisons

The ProLiant DL560 Gen11 packs four 4th Gen Xeon Scalable processors, 64 DDR5 slots and up to 24 drives into 2U. Its QuickSpecs read as a set of trade-offs rather than one specification: the air- or liquid-cooled chassis chosen at order decides which processors a four-socket build can use, and HPE’s thermal tables cap the inlet temperature for each mix of drives, DIMMs and cards.

2U Rack2 or 4 sockets4th Gen Xeon ScalableHPE iLO 6
4processor sockets2U · two- or four-socket builds
60cores per processor240 per server · Platinum 8490H
16TBDDR5 maximum64 × 256 GB · see memory notes
24front drive baysSFF, or E3.S with four CPUs
6PCIe 5.0 slotstwo 3-slot risers + 2 × OCP 3.0
4power supplies maxFlex Slot · 1+1, 2+2 or 3+1

Every figure checked against the HPE ProLiant DL560 Gen11 QuickSpecs (Version 33 - 03-Aug-2026)

Form factor
2U Rack · 4 sockets
Processors
4th Gen Xeon
Memory
64 × DDR5 RDIMM · up to 16.0 TB
Drive bays
Up to 24 · 4 drive-cage kits
Expansion
6 × PCIe · 2 × OCP 3.0
GPUs
Up to 2 · 1 listed
Boot
NS204i · 3 boot options
Management
HPE iLO 6
01 — Overview

The DL560 Gen11 at a glance

Our read of HPE’s documentation: where the DL560 Gen11 is strong, and the limits worth knowing before you spec one.

Strengths

  • 240 cores from four 60-core Platinum 8490H processors, with sixteen DIMM slots per socket, in a 2U chassis.
  • Up to 24 front SFF drives on tri-mode or NVMe cages, or 24 E3.S NVMe drives in a four-socket build, with a front media bay option in Box 1.
  • Two processors can run on their own: HPE lists a 2P air baffle and a UPI pass-through kit, and all nine processors are supported in the two-socket air-cooled build.
  • Five Flex Slot supplies — four AC units from an 800 W Platinum on 100–240 VAC to the 1800–2200 W Titanium, and one −48 VDC model — in 1+1, 2+2 or 3+1 redundancy.
  • Two risers of x8/x16/x8 or x16/x16/x16 give six full-height PCIe 5.0 slots, with two OCP 3.0 slots beside them.

Watch-outs

  • Only nine processors are listed, all 4th Gen H-series; the QuickSpecs offer no 5th Gen Xeon Scalable or Xeon 6 option.
  • Cooling is fixed at order and cannot be converted later: four-socket builds of the 6434H, 8444H, 8460H, 8468H and 8490H need the liquid-cooled chassis, leaving the 6416H, 6418H, 6448H and 8450H for four-socket air cooling.
  • The 16 TB ceiling depends on a 256 GB DIMM that appears only in HPE’s support matrix; the largest kit in the ordering lists is 128 GB, which makes 8 TB across 64 slots.
  • Thermal tables set the maximum inlet by processor, storage, DIMM size and network card — down to 20 °C for some four-socket builds — and many of HPE’s adapter tables allow 24 SFF drives on four air-cooled sockets only with the 6416H or 6418H.
  • The liquid-cooling heat sink kit is factory-fit only, has no leak detection and carries a five-year maximum usage limit, after which HPE requires its replacement.
Processors9 SKUs
Cores / CPU8–60
DIMM slots64
Drive-cage kits4
Max bays24
GPUsup to 2
PSU options5 · to 2,200 W
02 — Processors

9 supported processors, mapped

HPE lists nine processors, all 4th Gen Xeon Scalable H-series: five Platinum (8490H, 8468H, 8460H, 8450H, 8444H) and four Gold (6448H, 6434H, 6418H, 6416H), from 8 to 60 cores and 165 W to 350 W. A server runs two or four of the same model, and whether a four-socket build can use a given part depends on the cooling chosen at order.

Processor landscape — cores × TDP

9 SKUs · 1 family
HPE ProLiant DL560 Gen11: every supported processor by cores and TDP0816243240485664150 W200 W250 W300 W350 WCores per processorIntel Xeon-Platinum 8490H — 60 cores · 350 W · 1.9 GHz base · 112.5 MB cache · DDR5-4800Intel Xeon-Platinum 8468H — 48 cores · 330 W · 2.1 GHz base · 105 MB cache · DDR5-4800Intel Xeon-Platinum 8460H — 40 cores · 330 W · 2.2 GHz base · 105 MB cache · DDR5-4800Intel Xeon-Gold 6448H — 32 cores · 250 W · 2.4 GHz base · 60 MB cache · DDR5-4800Intel Xeon-Platinum 8450H — 28 cores · 250 W · 2 GHz base · 75 MB cache · DDR5-4800Intel Xeon-Gold 6418H — 24 cores · 185 W · 2.1 GHz base · 60 MB cache · DDR5-4800Intel Xeon-Gold 6416H — 18 cores · 165 W · 2.2 GHz base · 45 MB cache · DDR5-4800Intel Xeon-Platinum 8444H — 16 cores · 270 W · 2.9 GHz base · 45 MB cache · DDR5-4800Intel Xeon-Gold 6434H — 8 cores · 195 W · 3.7 GHz base · 22.5 MB cache · DDR5-4800Intel Xeon-Platinum 8490H60 cores · 5.8 W/core — top SKU and most efficient
4th Gen Xeon Scalable 9Bubble size = L3 cache · hover a bubble for the full SKU

Processor explorer

filter · sort · compare
ProcessorCores / threadsBaseL3 cacheTDPW / coreMemory
Intel Xeon-Platinum 8490H601.9 GHz112.5 MB350 W5.8DDR5-4800
Intel Xeon-Platinum 8468H482.1 GHz105 MB330 W6.9DDR5-4800
Intel Xeon-Platinum 8460H402.2 GHz105 MB330 W8.3DDR5-4800
Intel Xeon-Gold 6448H322.4 GHz60 MB250 W7.8DDR5-4800
Intel Xeon-Platinum 8450H282 GHz75 MB250 W8.9DDR5-4800
Intel Xeon-Gold 6418H242.1 GHz60 MB185 W7.7DDR5-4800
Intel Xeon-Gold 6416H182.2 GHz45 MB165 W9.2DDR5-4800
Intel Xeon-Platinum 8444H162.9 GHz45 MB270 W16.9DDR5-4800
Intel Xeon-Gold 6434H83.7 GHz22.5 MB195 W24.4DDR5-4800
  • In two-socket builds all nine processors are air-cooled; in four-socket builds the 6416H, 6418H, 6448H and 8450H are air-cooled and the 6434H, 8444H, 8460H, 8468H and 8490H need the Liquid Cooling CTO (P55182-B21).
  • UPI runs at 16 GT/s over four links in a two-socket build and three links in a four-socket build.
  • A two-socket server must be ordered with the 2P air baffle (P55550-B21) and the 2P UPI pass-through kit (P54806-B21); a 4P CPU mezzanine kit (P54803-B21) also appears among the key options.
  • Heat sinks: P48818-B21 for two-socket air cooling, P48905-B21 for four-socket air cooling, and the factory-fitted P54791-B21 kit for four-socket liquid cooling.
  • HPE notes that maximum memory per processor depends on the processor model and the storage layout, which its support matrix sets out.
03 — Memory

64 DIMM slots, 16 per processor

Each of the four processors has eight DDR5 channels with two slots apiece — 16 per socket and 64 in all. HPE rates the DDR5-4800 kits for 4800 MT/s at one DIMM per channel, falling to 4400 MT/s when a channel carries two. Its 16.0 TB maximum (64 × 256 GB) is printed at 4800 MT/s, although 64 DIMMs means two per channel, where the same document gives 4400 MT/s.

Capacity with every slot filled

by DIMM size
16 GB1 TB32 GB2 TB64 GB4 TB96 GB6 TBhalf or full load per CPU128 GB8 TBliquid CTO: quad-rank P63345-B21256 GB16 TBsupport matrix only64 slots · 16 per processor · each tick = one DIMM

Operating speed

per HPE memory tables
Processor1 DIMM / channel2 DIMMs / channel
4th Gen Xeon Scalable (H-series)4800 MT/s4400 MT/s
  • Per processor, HPE’s population table runs through 1, 2, 4, 6, 8, 12 or 16 modules — other counts lack Intel qualification — and the ordering notes ask for an even number of DIMMs.
  • The ordering lists offer 16, 32, 64, 96 and 128 GB RDIMMs; the 256 GB part (P43337-B21) and a second 128 GB part (P43334-B21) are named only as support-matrix columns.
  • On the liquid-cooled CTO, a 128 GB configuration has to use the quad-rank P63345-B21 module.
  • 96 GB modules go in at half or full population on every processor and cannot be mixed with other sizes.
  • HPE’s CPU/storage/memory support matrix lowers the maximum inlet temperature as DIMM size and drive count rise, reaching 20 °C in some four-socket rows.
04 — Storage

4 drive-cage kits, up to 24 bays

The front has three drive boxes. The base 8 SFF chassis grows to 24 SFF with tri-mode x1 or NVMe x4 cages, or takes 12-bay EDSFF cages — up to 16 E3.S drives with two processors and 24 with four. Boxes fill in a set order: Box 3 first on two-socket systems, Box 2 first on four-socket ones, with Box 1 last.

Headline layouts

front panel view

Front panel

Three 8SFF U.3 cages across Boxes 1–3; x1 tri-mode and x4 NVMe cages cannot be mixed. On four air-cooled sockets many adapter tables allow it only with the 6416H or 6418H (the DIMM matrix also shows a 20 °C row for the 250 W parts), and the adapter tables mark it not supported on the liquid-cooled model.

SAS/SATANVMeSAS/SATA + NVMe

Controllers & boot

  • Embedded Hybrid RAID with 8 SATA ports — Software RAID. Listed as the base storage controller on both CTO models (Step 1), alongside a choice of modular Smart Array and PCIe/OCP plug-in controllers.
  • HPE MR216i-p Gen11 x16 Lanes without Cache PCI SPDM Plug-in Storage Controller — RAID. Tri-Mode; PCIe plug-in
  • HPE MR216i-o Gen11 x16 Lanes without Cache OCP SPDM Storage Controller — RAID. Tri-Mode; OCP
  • HPE MR408i-o Gen11 x8 Lanes 4GB Cache OCP SPDM Storage Controller — RAID, 4GB cache. Tri-Mode; OCP; cached controllers require HPE 96W Smart Storage Battery (P01367-B21) or Smart Hybrid Capacitor (P02381-B21)
  • HPE MR416i-p Gen11 x16 Lanes 8GB Cache PCI SPDM Plug-in Storage Controller — RAID, 8GB cache. Tri-Mode; PCIe plug-in; requires battery or hybrid capacitor
  • HPE MR416i-o Gen11 x16 Lanes 8GB Cache OCP SPDM Storage Controller — RAID, 8GB cache. Tri-Mode; OCP; requires battery or hybrid capacitor
  • HPE SR932i-p Gen11 x32 Lanes 8GB Wide Cache PCI SPDM Plug-in Storage Controller — RAID, 8GB cache. Tri-Mode; PCIe plug-in; requires x16 physical and electrical riser slot; requires battery or hybrid capacitor
  • HPE Smart Array E208e-p SR Gen10 (8 External Lanes/No Cache) 12G SAS PCIe Plug-in Controller — RAID. Essential RAID controller; external SAS
  • HPE NS204i-u Gen11 NVMe Hot Plug Boot Optimized Storage Device (P48183-B21) — boot
  • HPE ProLiant DL560 Gen11 NS204i-u Front Enablement Kit (P55549-B21) — boot
  • HPE ProLiant DL380a/DL560 Gen11 NS204i-u Rear Enablement Kit (P55710-B21) — boot
All 12 controllers and 3 boot options
  • Intel Virtual RAID on CPU Premium FIO Software for HPE — Software RAID. Hybrid RAID; requires UEFI (not Legacy); NVMe SSDs only, no PCIe card support; RAID 0/1/5/10
  • Intel Virtual RAID on CPU Premium E-RTU for HPE — Software RAID. Hybrid RAID; UEFI only; NVMe SSDs only; RAID 0/1/5/10; for pre-configured (BTO) upgrade
  • Intel Virtual RAID on CPU (Intel VROC) Standard Software FIO for HPE — Software RAID. Named only in Standard Features 'Hybrid RAID' list; no SKU in Core Options.
  • HPE NS204i-u Gen11 NVMe Hot Plug Boot Optimized Storage Device — Boot. Max = 1. Front location (between fan cage and storage box) via NS204i-u Front Enablement Kit (P55549-B21) - 'Not hot-pluggable' in front; or rear in PCIe Riser 2 slot 4 via NS204i-u Rear Enablement Kit (P55710-B21), which needs a second riser and slot 5 kept empty. With liquid cooling and front NS204i-u, Media Bay not supported.
  • Tri-mode controllers are the uncached MR216i-p and MR216i-o, the MR408i-o (4 GB), the MR416i-p and MR416i-o (8 GB) and the SR932i-p (8 GB), which needs an x16 riser slot; cached controllers need a battery or hybrid capacitor.
  • The base controller is embedded hybrid RAID with eight SATA ports; Intel VROC Premium adds NVMe RAID 0/1/5/10 in UEFI mode, and the E208e-p connects external SAS.
  • Direct-attached and tri-mode-controlled drives cannot be mixed, and HPE’s tri-mode controllers do not support PE80xx NVMe drives.
  • The NS204i-u boot device mounts at the front between the fan cage and the drive boxes (not hot-pluggable) or at the rear in slot 4 of the second riser (hot-pluggable); a front boot device on a liquid-cooled server rules out the media bay.
  • A drive-less build still needs an x4 cage and a direct-attach cable, with no controller.
  • HPE’s maximum-storage table gives 368.64 TB for 24 × 15.36 TB SAS or NVMe SSDs and 57.6 TB for 24 × 2.4 TB SAS hard drives.

Every documented drive-cage kit

4 with drive bays
HPE ProLiant DL560 Gen11 8SFF x1 Tri-Mode U.3 Driv…HPE ProLiant DL560 Gen11 8SFF x1 Tri-Mode U.3 Drive Cage Kit8HPE ProLiant DL560 Gen11 8SFF x4 U.3 NVMe Drive Ca…HPE ProLiant DL560 Gen11 8SFF x4 U.3 NVMe Drive Cage Kit8HPE ProLiant DL560 Gen11 2SFF U.3 Drive Cage KitHPE ProLiant DL560 Gen11 2SFF U.3 Drive Cage Kit2HPE ProLiant DL560 Gen11 12EDSFF Drive Cage KitHPE ProLiant DL560 Gen11 12EDSFF Drive Cage Kit12Bays · solid = front · dashed = rear · brighter = NVMe-only
2.5-inch3.5-inchEDSFF (E1.S / E3.S)
05Accelerators & I/O

GPUs, PCIe and networking

GPU support is narrow. Double-wide cards can only sit in slot 2 of the primary riser and slot 5 of the secondary, at up to 10.5 inches long, with the GPU Enablement Kit (P54816-B21). The NVIDIA L40 48 GB is the one accelerator with an option part number; HPE’s thermal table allows it at up to 30 °C with a single drive box, 30 °C or less with two, and not at all with 24 SFF drives or on the liquid-cooled four-socket model. A second table is headed H100 80GB but carries no option part, and the change log records a graphics-accelerator SKU removed in version 22. Up to 2 double-wide GPUs (slots 2 and 5) · NVIDIA L40 48 GB · air-cooled builds only

NVIDIA L40 48GB PCIe Accelerator for HPE

double-wide
48GB · up to 2 (slot 2 primary riser, slot 5 secondary riser)

I/O topology

4 sockets
CPU 1PCIe 5.08 ch · 16 DIMMCPU 2PCIe 5.08 ch · 16 DIMMCPU 3PCIe 5.08 ch · 16 DIMMCPU 4PCIe 5.08 ch · 16 DIMMUPI · 4 links (2P) / 3 (4P) · 16 GT/sRiser: x8 / x16 / x8P54779-B21 · FH ¾-lengthRiser: 3 × x16P54780-B21 · slot 1 cabled2 × OCP 3.0x16 via mobo (2P) / mezz (4P) kitiLO 6 · 1 Gb rear portplus front iLO service port

Two riser positions each take an x8/x16/x8 or an x16/x16/x16 PCIe 5.0 riser with full-height, three-quarter-length slots. On the x16/x16/x16 riser the first slot is cabled — to processors 1 or 2 in a two-socket server, 3 or 4 in a four-socket one — through a motherboard or mezzanine cable kit. Two OCP 3.0 slots sit alongside, and there is no embedded LAN.

Network adapters HPE lists

33 options
AdapterPortsForm
Broadcom BCM5719 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE4 × 1GbEOCP 3.0
Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE4 × 1GbEOCP 3.0
Broadcom BCM57416 Ethernet 10Gb 2-port BASE-T OCP3 Adapter for HPE2 × 10GbEOCP 3.0
Broadcom BCM57412 Ethernet 10Gb 2-port SFP+ OCP3 Adapter for HPE2 × 10GbEOCP 3.0
Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE4 × 10/25GbEOCP 3.0
Broadcom BCM57414 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE2 × 10/25GbEOCP 3.0
Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE2 × 10/25GbEOCP 3.0
Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE2 × 10/25GbEOCP 3.0
Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter for HPE2 × 100GbEOCP 3.0
Broadcom BCM57608 Ethernet 100Gb 2-port QSFP112 OCP3 Adapter for HPE2 × 100GbEOCP 3.0
Broadcom BCM5719 Ethernet 1Gb 4-port BASE-T Adapter for HPE4 × 1GbEPCIe
Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE4 × 1GbEPCIe
Broadcom BCM57416 Ethernet 10Gb 2-port BASE-T Adapter for HPE2 × 10GbEPCIe
Broadcom BCM57412 Ethernet 10Gb 2-port SFP+ Adapter for HPE2 × 10GbEPCIe
NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE2 × 10/25GbEPCIe
Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE4 × 10/25GbEPCIe
Broadcom BCM57414 Ethernet 10/25Gb 2-port SFP28 Adapter for HPE2 × 10/25GbEPCIe
Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter for HPE2 × 10/25GbEPCIe
Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE4 × 10/25GbEPCIe
Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE2 × 10/25GbEPCIe
Broadcom BCM57608 Ethernet 100Gb 2-port QSFP112 Adapter for HPE2 × 100GbEPCIe
Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE2 × 100GbEPCIe
NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE2 × 100GbEPCIe
Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter for HPE2 × 100GbEPCIe
HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Generic Adapter1 × NDR200 InfiniBand / 200GbEPCIe
HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter1 × 32Gb Fibre ChannelPCIe
HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter2 × 32Gb Fibre ChannelPCIe
HPE SN1700E 64Gb 1-port Fibre Channel Host Bus Adapter1 × 64Gb Fibre ChannelPCIe
HPE SN1700E 64Gb 2-port Fibre Channel Host Bus Adapter2 × 64Gb Fibre ChannelPCIe
HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter1 × 32Gb Fibre ChannelPCIe
HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter2 × 32Gb Fibre ChannelPCIe
HPE SN1700Q 64Gb 1-port Fibre Channel Host Bus Adapter1 × 64Gb Fibre ChannelPCIe
HPE SN1700Q 64Gb 2-port Fibre Channel Host Bus Adapter2 × 64Gb Fibre ChannelPCIe
  • With one riser the factory fits it in the primary position; with two, the x16/x16/x16 riser goes in the primary position.
  • x16 cards fitted in x8 slots may see reduced performance.
  • OCP at x16 needs the OCP x16 to Motherboard Enablement Kit (P55322-B21) on two-socket builds or the Mezzanine Board kit (P55324-B21) on four-socket builds.
  • Some network adapters must go in riser 1 or in OCP2, and each carries its own inlet limits in HPE’s adapter tables.
  • Rear ports are VGA, two USB 3.2, the 1 Gb iLO port and an optional serial port (cable kit P48824-B21); the media bay’s front DisplayPort and the rear VGA cannot be active together.
06 — Power & cooling

5 power supplies, 800–2,200 W

Two to four HPE Flex Slot hot-plug supplies, all the same model, in 1+1, 2+2 or 3+1 redundancy. Low-line and high-line sites can both use the 800 W Platinum and 1000 W Titanium units; the 1600 W Platinum and the Titanium unit rated 1800–2200 W are high-line only, and a 1600 W −48 VDC unit covers DC sites.

05001000150020002500800 W Platinum — HPE 800W Flex Slot Platinum Hot Plug Low Halogen Power Supply Kit; HPE Flex Slot family; up to 94% efficiency; C-14 inlet; 800W at 100/240 VAC (240 VDC China only)800Platinum1000 W Titanium — HPE 1000W Flex Slot Titanium Hot Plug Power Supply Kit; HPE Flex Slot family; up to 96% efficiency; C-14 inlet; EU ErP Lot 9 compliant (96%). Standard Features calls it '...Hot Plug Low Halogen Power Supply Kit'.1000Titanium1600 W null — HPE 1600W Flex Slot -48VDC Hot Plug Power Supply Kit; HPE Flex Slot family; Standard Features names it 'HPE 1600W FS 48VDC Hot Plug LH Power Supply Kit' with '94% efficiency'; no 80 PLUS tier printed. Tech Specs rated steady-state/peak shows 800W (at -40 Vdc / -72 Vdc) - contradicts 1600W name.1600DC1600 W Platinum — HPE 1600W Flex Slot Platinum Hot Plug Low Halogen Power Supply Kit; HPE Flex Slot family; up to 94% efficiency; C-14 inlet; Core Options note calls it 'Platinum Plus'1600Platinum2200 W Titanium — HPE 1800W-2200W Flex Slot Titanium Hot Plug Power Supply Kit; HPE Flex Slot family; up to 96% efficiency; C-14 inlet; 1800W-2200W at 200-240 VAC, 2200W at 240 VDC (China only); output capped at 1600W on Gen10/Gen10 Plus; EU ErP Lot 9 compliant (96%)2200TitaniumWatts · dashed line = output at 100–120 V low line
AC−48 V DC
  • HPE lists a 4x Power Supply Enablement Kit (P54812-B21) among the key options.
  • The −48 VDC unit is sold as 1600 W, but the technical specifications print its rated output as 800 W at −40 and −72 VDC.
  • The 1000 W and 1800–2200 W Titanium units (P03178-B21, P44712-B21) are among the part numbers HPE cites as 96% efficient for EU ErP Lot 9, which covers units sold into the UK.
  • The 1800–2200 W Titanium supply is capped at 1600 W in Gen10 and Gen10 Plus servers; output above 1600 W needs a Gen11 server such as this one.
  • Fans: six high-performance fans on the Air Cooling CTO (P55181-B21), five performance fans on the Liquid Cooling CTO (P55182-B21).
  • In HPE’s acoustic declaration the entry configuration measured 5.6 B operating and the performance configuration 6.1 B.
07 — Management, security & OS

Run it, secure it, choose the OS

Management

  • HPE iLO 6 (iLO 6 ASIC) with Intelligent Provisioning; iLO Advanced and OneView optional
  • Three-year HPE Compute Ops Management subscription added by default
  • iLO RESTful API (Redfish), RESTful Interface Tool and scripting tools
  • Active Health System, Smart Update Manager and iLO Amplifier Pack
  • Optional Systems Insight Display (the front iLO service port is then unavailable)

Security

  • Immutable Silicon Root of Trust with Secure Recovery
  • UEFI Secure Boot and Secure Start; digitally signed firmware with rollback
  • Embedded TPM 2.0 — no TPM module kit needed
  • FIPS 140-2 validation and Common Criteria certification
  • CNSA support; configurable for PCI DSS
  • Bezel lock and chassis-intrusion detection options
  • Platform Certificate and IDevID iLO FIO setting (P42104-B21)

Operating systems

  • Supported operating systems and hypervisors are published in HPE’s Servers Support & Certification Matrices rather than in the QuickSpecs
  • Intel VROC out-of-band Redfish management does not work with Secure Boot on Linux kernel 5.4 or later (HPE advisory a00128934en_us)
  • UEFI Class 3; TPM 2.0, NVMe boot and HTTP/HTTPS boot in UEFI mode
08 — Compare

How the DL560 Gen11 compares with its family

The bars set the DL560 Gen11 beside the HPE rack servers nearest to it in our spec set — the DL580 Gen12, the DL380 Gen11 and Gen12, and the DL360 Gen11 — from each model’s verified spec file.

DL560 Gen11DL580 Gen12DL380 Gen11DL380 Gen12DL360 Gen11Cores / CPUDL560 Gen11: 6060DL580 Gen12: 8686DL380 Gen11: 6464DL380 Gen12: 144144DL360 Gen11: 6464DIMM slotsDL560 Gen11: 6464DL580 Gen12: 6464DL380 Gen11: 3232DL380 Gen12: 3232DL360 Gen11: 3232Max memoryDL560 Gen11: 16 TB16DL580 Gen12: 16 TB16DL380 Gen11: 8 TB8DL380 Gen12: 8 TB8DL360 Gen11: 8 TB8Max drive baysDL560 Gen11: 2424DL580 Gen12: 3232DL380 Gen11: 3636DL380 Gen12: 3636DL360 Gen11: 2020Max GPUsDL560 Gen11: 22DL580 Gen12: 00DL380 Gen11: 88DL380 Gen12: 88DL360 Gen11: 33Largest PSUDL560 Gen11: 2,200 W2,200DL580 Gen12: 3,200 W3,200DL380 Gen11: 2,200 W2,200DL380 Gen12: 2,200 W2,200DL360 Gen11: 2,200 W2,200
This modelSiblings and successorEach value from that model’s own verified spec file · bars scale per column
09 — Use cases

Four builds that suit the DL560 Gen11

Four DL560 Gen11 builds from options our configurator permits on this server. Each opens pre-filled with one drive cage and two supplies; where HPE’s rules call for more cages, more supplies or a particular cooling model, the lines say so and we set it on the quote.

In-memory database

8 TB four-socket, liquid-cooled

Four 60-core Platinum 8490H processors and 64 × 128 GB RDIMMs give 240 cores and 8 TB, the most memory the ordering lists can supply. At 350 W the 8490H needs the liquid-cooled chassis in four-socket form, and eight direct-attached NVMe drives in one box hold logs and data files.

  • 4 × Xeon-Platinum 8490H60 cores @ 1.9 GHz, 350 W each
  • 64 × 128 GB DDR5-4800 RDIMM — 8 TB, two per channel (4400 MT/s); quad-rank P63345-B21 on the liquid-cooled CTO
  • 8 × 7.68 TB U.3 NVMe in one x4 cage, direct-attached
  • Intel VROC NVMe RAID (licence quoted separately)
  • NS204i-u NVMe boot device
  • Broadcom BCM57608 2 × 100 GbE QSFP112 OCP3
  • 2 × 1800–2200 W Flex Slot Titanium — up to four supported; size with HPE Power Advisor
  • Liquid Cooling CTO (P55182-B21) with the P54791-B21 heat sink kit
  • SUSE Linux Enterprise Server 15
  • HPE Tech Care Critical

The liquid-cooling kit is factory-installed, has no leak detection and must be replaced after five years of operation. HPE’s liquid-cooled matrix allows 96 GB and 128 GB modules up to 30 °C inlet with one 8 SFF box. Four-socket storage starts in Box 2.

Open this build in the configurator →
Virtualisation & consolidation

Four-socket air-cooled consolidation host

Four 32-core Gold 6448H processors — the highest core count HPE allows in a four-socket air-cooled build — give 128 cores, with 32 × 64 GB RDIMMs (2 TB) at one DIMM per channel for 4800 MT/s. SAS SSDs on a cached tri-mode controller hold the VM datastores.

  • 4 × Xeon-Gold 6448H32 cores @ 2.4 GHz, 250 W each
  • 32 × 64 GB DDR5-4800 RDIMM — 2 TB, one per channel
  • 8 × 3.84 TB SAS SSD in an 8SFF tri-mode cage — a second cage and eight more drives set on the quote for 16
  • HPE MR416i-p Gen11 tri-mode controller, 8 GB cache, with battery or hybrid capacitor
  • NS204i-u NVMe boot device
  • Broadcom BCM57504 4 × 10/25 GbE SFP28 OCP3
  • 2 × 1600 W Flex Slot Platinum (200–240 VAC)
  • Air Cooling CTO (P55181-B21) with P48905-B21 heat sinks
  • Windows Server 2025 Datacenter
  • HPE Tech Care Essential

In HPE’s four-socket air matrix (processors up to 250 W), two 8 SFF boxes allow 30 °C inlet with 64 GB or smaller DIMMs. An air-cooled server cannot later be converted to liquid cooling.

Open this build in the configurator →
Analytics with GPU assist

Two-socket build with two L40 cards

Two 48-core Platinum 8468H processors run on their own with the 2P baffle and UPI pass-through kits, leaving riser slots 2 and 5 for two L40 GPUs. Memory is 1 TB from sixteen 64 GB modules, one per channel, and eight E3.S drives fill a 12-bay EDSFF cage to its two-socket limit.

  • 2 × Xeon-Platinum 8468H48 cores @ 2.1 GHz, 330 W each
  • 2 × NVIDIA L40 48 GB in slots 2 and 5, with the GPU Enablement Kit (P54816-B21)
  • 16 × 64 GB DDR5-4800 RDIMM — 1 TB, one per channel
  • 8 × 7.68 TB E3.S NVMe in a 12EDSFF cage (eight per box on two sockets)
  • NS204i-u NVMe boot device
  • Broadcom BCM57414 2 × 10/25 GbE SFP28 OCP3
  • 2 × 1800–2200 W Flex Slot Titanium
  • 2P air baffle (P55550-B21) and UPI pass-through (P54806-B21) kits
  • Red Hat Enterprise Linux 9
  • HPE Tech Care Essential

HPE’s L40 table allows 30 °C inlet with one EDSFF box on a two-socket air-cooled server and 25 °C with two; the card is not supported on the liquid-cooled four-socket model. Each GPU needs a riser in its position.

Open this build in the configurator →
Database & storage-heavy

24-SFF four-socket database server

Filling all three boxes gives 24 SFF bays for database files and logs. Many of HPE’s adapter tables allow that on four air-cooled sockets only with the 165 W 6416H or the 185 W 6418H, so this build uses four 24-core 6418H processors (96 cores), an SR932i-p controller and 32 × 64 GB of memory.

  • 4 × Xeon-Gold 6418H24 cores @ 2.1 GHz, 185 W each
  • 32 × 64 GB DDR5-4800 RDIMM — 2 TB, one per channel
  • 8 × 7.68 TB SAS SSD in one tri-mode cage — two more cages and 16 more drives set on the quote for 24
  • HPE SR932i-p Gen11 tri-mode controller, 8 GB wide cache, in an x16 riser slot
  • NS204i-u NVMe boot device
  • Broadcom BCM57414 2 × 10/25 GbE SFP28 OCP3
  • 2 × 1600 W Flex Slot Platinum (200–240 VAC)
  • Air Cooling CTO (P55181-B21)
  • Windows Server 2025 Standard
  • HPE Tech Care Basic

On four air-cooled sockets HPE’s adapter tables give this layout 20–30 °C or no support, depending on the card, while the DIMM matrix lists 35 °C for it with 64 GB modules on the 6416H and 6418H; the adapter tables mark it not supported on the liquid-cooled model. Cached controllers need a battery or hybrid capacitor.

Open this build in the configurator →
10 — Refurbished alternatives

When a refurbished ProLiant makes more sense

None of the refurbished ProLiant models we configure has four sockets. Where two sockets and DDR4 are enough — a consolidation or database host that does not need 64 DIMM slots — these earlier 2U servers are the refurbished options.

Gen10 Plus · re-certified

HPE ProLiant DL380 Gen10 Plus

  • 2U · two Ice Lake Xeon processors
  • 32 DIMM slots · 8 TB DDR4
  • 24 × SFF or 12 × LFF bays
  • PCIe 4.0 · OCP 3.0 · iLO 5

A two-socket Intel host with up to 8 TB of DDR4 for database or virtualisation work that fits in half the DL560’s sockets.

Configure a refurbished DL380 Gen10 Plus
Gen10 Plus · re-certified

HPE ProLiant DL385 Gen10 Plus

  • 2U · two AMD EPYC 7002/7003
  • Up to 128 cores · 32 DIMM slots
  • 8 TB DDR4-3200, 8-channel
  • 24 × SFF or 12 × LFF · iLO 5

When total core count matters more than socket count: two EPYC processors with up to 128 cores between them.

Configure a refurbished DL385 Gen10 Plus
11 — Full specifications

HPE ProLiant DL560 Gen11 specifications

Chassis & cooling

Form factor2U rack · four-socket
CTO modelsP55181-B21 Air Cooling · P55182-B21 Liquid Cooling (no later conversion)
Dimensions (H × W × D)8.75 × 43.3 × 80.6 cm (SFF CTO)
WeightAir 21.08–38.02 kg · liquid 26.83–36.93 kg
Fans6 high-performance (air CTO) · 5 performance (liquid CTO)
Liquid coolingClosed-loop kit P54791-B21 · factory-fit · 5-year usage limit
RailsBall Bearing Rail 8 Kit P61501-B21 · CMA P28726-B21 separate

Processor

Sockets2 or 4, same model
Family4th Gen Xeon Scalable — Platinum 84xxH, Gold 64xxH
Cores per processor8 to 60
TDP165 W to 350 W
UPI16 GT/s · 4 links (2P) · 3 links (4P)
ChipsetIntel C741

Memory

Slots64 DDR5 RDIMM · 16 per processor · 8 channels × 2 DPC
Speed4800 MT/s (1 DPC) · 4400 MT/s (2 DPC)
Ordering-list kits16, 32, 64, 96, 128 GB RDIMM
Maximum16.0 TB (64 × 256 GB) as printed · 8 TB with 128 GB kits

Storage

FrontUp to 24 SFF (3 × 8) · 16 E3.S (2P) or 24 E3.S (4P)
Media bayBox 1 only · 2 SFF/NVMe, DisplayPort, 2 × USB 2.0, optical
Maximum (HPE table)368.64 TB (24 × 15.36 TB SAS or NVMe SSD)
ControllersEmbedded 8-port SATA hybrid RAID · Intel VROC · MR216i-p/-o, MR408i-o, MR416i-p/-o, SR932i-p · E208e-p
BootNS204i-u — front, or rear in slot 4

Expansion & networking

PCIeUp to 6 × PCIe 5.0, full height, ¾ length, on 2 risers
OCP2 × OCP 3.0
LANNone embedded
GPUUp to 2 double-wide (slots 2 and 5) · NVIDIA L40 48 GB

Power

SuppliesFlex Slot: 800 W Platinum, 1000 W Titanium, 1600 W Platinum, 1800–2200 W Titanium, 1600 W −48 VDC
Quantity2 to 4, matched · 1+1, 2+2 or 3+1
Input100–240 VAC (800 W, 1000 W) · 200–240 VAC (1600 W, 1800–2200 W) · −40 to −72 VDC (−48 VDC unit)

Ports & video

FrontUSB 3.2 · iLO service port · optional DisplayPort and 2 × USB 2.0 (media bay)
Rear2 × USB 3.2 · VGA · 1 Gb iLO · optional serial
Internal1 × USB 3.2 · 1 × USB 2.0
Video1920 × 1200 at 60 Hz · 16 MB

Environment & warranty

Operating temperature10–35 °C · 5–10 °C, 35–40 °C and 40–45 °C extended for approved configurations
Maximum altitude3,050 m
Acoustics (operating)5.6 B entry · 6.1 B performance
Warranty3 years parts, labour and onsite, next business day
12 — FAQ

DL560 Gen11 questions, answered from the documentation

What is the maximum memory of the HPE ProLiant DL560 Gen11?

HPE quotes 16.0 TB from 64 × 256 GB RDIMMs. That 256 GB module appears only in the support matrix, not in the ordering lists, whose largest kit is 128 GB — 8 TB across the 64 slots. A second DIMM on a channel brings the speed down from 4800 MT/s to 4400 MT/s.

How many processors does the DL560 Gen11 take?

Two or four of the same model, chosen from nine 4th Gen Xeon Scalable H-series parts of 8 to 60 cores. With four processors, the 6416H, 6418H, 6448H and 8450H can be air-cooled, while the 6434H, 8444H, 8460H, 8468H and 8490H need the liquid-cooled chassis.

Can the DL560 Gen11 run with only two processors?

Yes. Two-socket builds use the 2P air baffle and UPI pass-through kits, run all nine processors air-cooled over four UPI links, and populate the 32 DIMM slots belonging to those two processors. They are limited to 16 E3.S drives, against 24 with four sockets.

How many drives does the DL560 Gen11 hold?

Up to 24 SFF drives in three 8-bay boxes, or up to 24 E3.S NVMe drives with four processors (16 with two). A Universal Media Bay in Box 1 adds two SFF or NVMe drives and front ports. On four air-cooled sockets, many of HPE’s adapter tables allow 24 SFF only with the 6416H or 6418H.

Does the DL560 Gen11 support GPUs?

Two double-wide cards can go in slots 2 and 5 with the GPU Enablement Kit, at up to 10.5 inches long. The NVIDIA L40 48 GB is the only accelerator with an option number, and HPE’s thermal table rules it out of liquid-cooled four-socket and 24-SFF builds.

How many PCIe slots does the DL560 Gen11 have?

Up to six PCIe 5.0 full-height slots on two risers, each x8/x16/x8 or x16/x16/x16, with a pair of OCP 3.0 slots alongside. No network port is built in, so every order includes an OCP or PCIe adapter.

Which power supplies does the DL560 Gen11 use?

Two to four matching Flex Slot supplies in 1+1, 2+2 or 3+1 redundancy: 800 W Platinum or 1000 W Titanium on 100–240 VAC, 1600 W Platinum or 1800–2200 W Titanium on 200–240 VAC, or a 1600 W −48 VDC unit.

How big and heavy is the DL560 Gen11?

The SFF chassis measures 8.75 × 43.3 × 80.6 cm. HPE gives 21.08 to 38.02 kg for air-cooled builds and 26.83 to 36.93 kg for liquid-cooled builds.

How does the DL560 Gen11 compare with the DL580 Gen12?

Going by the two QuickSpecs, the DL580 Gen12 is a 4U server for Intel Xeon 6 P-core processors, field-upgradeable from two to four sockets, with 64 slots for 16 TB (6400 MT/s at one DIMM per channel, 5200 MT/s at two), up to 32 SFF or EDSFF drives and iLO 7. The DL560 Gen11 fits four 4th Gen H-series processors in 2U with DDR5-4800, 24 front bays and iLO 6.

Is the HPE ProLiant DL560 Gen11 end of life?

Version 33 of the QuickSpecs (3 August 2026) sets no end-of-sale or end-of-support date. What its change log removes are options — SSD families, InfiniBand adapters and tape drives. Our end-of-life checker will show dates if HPE announces them.

Sources & verification

Where these figures come from

Specifications are extracted from HPE’s published documents and independently re-checked line by line. Configurations are quote-based; availability and exact options are confirmed at quotation. Last reviewed 2026-09-11.

Get a quote for the HPE ProLiant DL560 Gen11

Tell us the workload and we’ll spec and price it — or build it in the configurator first.

Business enquiries only — please use your company email. Gmail, Hotmail and other personal addresses are not accepted.

We only ship hardware to the countries in the dropdown. Software and maintenance services are global.

Enquiring about: HPE ProLiant DL560 Gen11

Response within 4 business hours · No obligation

Quote for
HPE ProLiant DL560 Gen11
0800 987 4111

Talk to a UK specialist

Get expert advice or a no-obligation quote — servers, storage, networking, maintenance, finance and cloud. We reply the same working day.

or call 0800 987 4111